HW108 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Triads Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Triads

HW108 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Triads Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Triads

Select gauge from drop-down menu for prices:

HW108 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Triads Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Triads
HW108 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Triads Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Triads
Technical Specifications:
Catalog Number HW108 01812
Size AWG 18
No. of Triads
12
PVC Insulation Thickness Mils 15
Nylon Jacket Thickness Mils 4
Overall Jacket Thickness Mils
80
Overall Diameter Inch 0.98
Net Weight Lbs/Mft
538

Specifications:

  • HW108
  • Instrumentation Cable
  • 600 Volt UL Type TC, 90°C
  • Multiple Triads
  • Individual and Overall Shield
  • TFN Insulation
  • PVC Jacket
  • Copper Conductors

Application:
For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations. UL approved for NEC continuous operation at 75ºC in wet locations, 90ºC in dry locations, 130ºC for emergency overland conditions, and 250ºC for short circuit locations.

Conductors:
7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8. Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire.

Insulation Jacket:
Clear nylon per UL Standard 62 for Type TFN wire.

Individual Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.

Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.

Jacket:
Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.

Flame Tests:
UL 1581 70,000 BTU/hr flame test

Color Code:

  • ICEA Method 1: black, white and red triads with printed number
  • Available upon request: black, red and blue triads with printed number

Additional Standards:

  • NEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725
  • NEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760