Technical Specifications:
Phase Conductor Insulation Thickness:45 mls
Size AWG:6
Stranding (Al/Stl):7
Diameter Complete Cable (O.D.) (Mils):267
Weight Per 1000ft Total (Lbs.):99
Allowable Ampacity 60C (Amps):55
Allowable Ampacity 75C (Amps):65
Allowable Ampacity 90C (Amps):75

Applications:
Type XHHW-2 conductors are primarily used in conduit or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code. XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90° C. Voltage rating for XHHW-2 conductors is 600 volts.

Specifications:
Type XHHW-2 conductors meet or exceed UL Standard 44; ASTM B3, B8;Federal Specification A-A-59544, and requirements of the National Electrical Code.
Type XHHW-2 meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) - Nonshielded 0 - 2 kV Cables, with testing frequencies based on UL requirements.

Construction:
Type XHHW-2 copper conductors are annealed (soft) copper. Insulation is an abrasion, moisture, and heat resistant cross-linked polyethylene (XLP). Colors available in sizes 14 AWG and larger. Sunlight Resistant in black only. Not CT rated. Conductor sizes 2 AWG and larger listed and marked sunlight resistant in black only.


Quick Quote Form 

* Indicates required field

Receive A Response In 5 Minutes Or Less During Regular Business Hours

Captcha Image

This product has no related products.

Related Products

Copper Type XHHW-2 conductors are created out of annealed soft copper that can conduct a very high load of electricity. In fact, copper is the most conductive metal outside of the precious metals group. That combined with its abundance and affordability makes it easy to see why half of all mined copper is used in wiring.

Copper XHHW conductors are designed for use in conduits and in other recognized raceways as feeders, services, and branch circuit wiring. This type of wiring can be used in a variety of different environments, including areas where the wiring will be exposed to water or moisture. The maximum voltage for Type XHHW-2 wiring is 600 volts, and it should not be used in an area where the conductor temperature will exceed 90 degrees Celsius. Other than that, this is a fairly flexible wire that has a variety of uses.

XHHW wiring comes in a variety of sizes.

Popular Products