Belden 1506A Cable 20 AWG Precision Video Coax Individual Jacket RG-59/U Type Cable

Belden 1506A Cable 20 AWG Precision Video Coax Individual Jacket RG-59/U Type Cable

Select gauge from drop-down menu for prices:

Belden 1506A Cable 20 AWG Precision Video Coax Individual Jacket RG-59/U Type Cable

Regular price $1,230.00 $820.00 Sale /per Foot

Belden 1506A Cable 20 AWG Precision Video Coax Individual Jacket RG-59/U Type Cable

Description:
• 20 AWG solid .032" bare copper conductor, plenum, foam FEP insulation, Duofoil® + tinned copper braid shield (95% coverage), Flamarrest® jacket.

Insulation:
• Trade Name: Teflon®
• Material: FFEP - Foam Fluorinated Ethylene Propylene
• Diameter (in.): 0.133

Outer Jacket:
• Trade Name: Flamarrest®
• Material: PVC - Polyvinyl Chloride

Usage (Overall):
Applications:
• SMPTE 2081-1 6 Gb/s UHDTV, SMPTE 424M 3 Gb/s HD-SDI 1080p

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 75°C
• Bulk Cable Weight: 29 lbs/1000 ft.
• Max. Recommended Pulling Tension: 68 lbs.
• Min. Bend Radius/Minor Axis: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• RG Type: 59/U

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75
• Nom. Inductance (μH/ft): 0.097
• Nom. Capacitance Conductor to Shield (pF/ft): 16.1
• Nominal Velocity of Propagation: VP (%): 84
• Nominal Delay (ns/ft): 1.21
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 10.0
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.2
• Max. Operating Voltage - UL: 300 V RMS
• Sweep Test: 100% Sweep tested 5 MHz to 6 GHz.

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 1505A

technical specification:
awg 20
# coax 1
stranding solid
no. of conductors 1
conductor material bare copper
dia. (in.) 0.032
outer shield - type tape
outer shield - material aluminum foil-polyester tape-aluminum foil
overall cable - nominal diameter (in.) 0.196
belden cable part number 1506A