Belden 9406 22 AWG 2 Pairs Audio Control and Instrumentation Multi Conductor Paired PVC Jacket Cable

Belden 9406 22 AWG 2 Pairs Audio Control and Instrumentation Multi Conductor Paired PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9406 22 AWG 2 Pairs Audio Control and Instrumentation Multi Conductor Paired PVC Jacket Cable

Regular price $1.94 $1.29 Sale /per Foot

Belden 9406 22 AWG 2 Pairs Audio Control and Instrumentation Multi Conductor Paired PVC Jacket Cable

Description:
• 22 AWG stranded (7x30) TC conductors, semi-rigid PVC insulation, twisted pairs, individually shielded w/Beldfoil® (100% coverage), 22 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.279

Inner Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.838

Mechanical Charactertistics (Overall):
• Bulk Cable Weight: 44.646 Kg/Km
• Max. Recommended Pulling Tension: 160.135 N
• Min. Bend Radius/Minor Axis: 44.450 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 50
• Nom. Inductance (μH/m): 0.311695
• Nom. Capacitance Conductor to Conductor (pF/m): 164.05
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 311.695
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 49.215
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 42.653 Ohm/km
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2464)
• Max. Recommended Current: 2.3 Amps/Conductor @ 25°C

Flame Test:
• C(UL) Flame Test: FT4

technical specification:
awg 22
# pairs 2
stranding 7x30
no. of conductors 4
conductor material tinned copper
outer shield - material unshielded
overall cable- nominal dia. (mm) 4.394 x 7.112
belden cable part number 9406