Belden 3090CE 16 AWG 1 Pair 600V Multi Conductor XLPE Insulation Tray Cable

Belden 3090CE 16 AWG 1 Pair 600V Multi Conductor XLPE Insulation Tray Cable

Regular price $1.83 $1.22 Sale /per Foot

Product Details

Description:
• 16 AWG stranded (7x24) bare copper conductors, twisted pairs, XLPE insulation, overall Beldfoil® shield (100% coverage), drain wire, insulated green ground wire, ripcord, PVC jacket.

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 16
• Ground Wire Stranding: 7x24
• Ground Wire Conductor Material: BC - Bare Copper
• Ground Wire Insulation Material: XLPE - Cross Linked Polyethylene

Insulation:
• Material: XLPE - Cross Linked Polyethylene

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.2192
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 78 lbs/1000 ft.
• Max. Recommended Pulling Tension: 130 lbs.
• Min. Bend Radius/Minor Axis: 3.900 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER, UL 1277
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 08/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-66-524

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Shield (pF/ft): 61.2
• Nom. Mutual Capacitance (pF/ft): 34
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.67
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.99
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202/383
• ICEA Flame Test: T-29-520

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 16
# paris 1
stranding 7x24
no. of conductors 3
conductor material bare copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 9.906
belden cable part number 3090CE

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question