Description:
• 16 AWG pairs stranded (7x24) bare copper conductors, twisted pairs, individually shielded plus an overall Beldfoil shield (100% coverage), PVC insulation, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride

Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drian Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Shield Drian Wire AWG:
• AWG: 16
• Stranding: 7x24
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.3462
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 239.600 Kg/Km
• Max. Recommended Pulling Tension: 1031.982 N
• Min. Bend Radius/Minor Axis: 114.300 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 196.86
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/m): 360.91
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 12.0413 (16 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 48.2307 (22 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 10.8273
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 16.635 Ohm/km
• Max. Operating Voltage - UL: 300 V RMS

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
• ICEA Flame Test: T-29-520

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 16
# pairs 2
stranding 7x24
no. of conductors 5
conductor material bare copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 11.608
belden cable part number 1492A