Product Information
Product Details
Conductor:2 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Insulation: Ethylene Propylene Rubber (EPR) insulation, colored
Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice
Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172
Shield: A flexible coated copper braid shield under an aluminum tape provides protection from radiated noise and a low transfer impedance path for the high frequency components of PWM signals
Jacket: Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE VFD-BGC 2000 VOLTS 07-KA140006 MSHA
Options:
• Colored jackets are available
• Anamaxx® jacket
Applications:
• Designed for use as a trailing cable on AC mining equipment:
- From the inverter to the motor on variable frequency drive (PWM) systems
- Where radiated EMI is causing interference with nearby systems
- Where a ground-check conductor is required for fail-safe ground monitoring
- With wireless ground monitoring systems
Features:
• Flexible overall shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced three-phase system and minimizes common mode current in PWM drive systems
• Enhanced ground-check conductor has longer flex life and durability
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures
Compliances:
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection
Packaging: Material cut to length and shipped on non-returnable reels
| technical specification: | |
| cond. size (awg/ kcmil) | 350 |
| no. of cond. | 3 |
| cond. strand | 851 |
| nominal insulation thickness(inches) | 0.095 |
| nominal insulation thickness(mm) | 2.4 |
| grd. cond. size(awg) | 1 |
| grd-check cond. size (awg) | 16 |
| nominal jacket thickness(inches) | 0.220 |
| nominal jacket thickness(mm) | 5.6 |
| nominal cable 0.d.(inches) | 2.64 |
| nominal cable 0.d.(mm) | 67.0 |
| copper weight(lbs/1000 ft) | 4384 |
| copper weight(kg/km) | 2937 |
| net weight(lbs/1000 ft) | 7480 |
| net weight(kg/km) | 11132 |
| ampacity | 435 |
| catalog number | 13373.036200 |