Conductor: Soft annealed tin plated copper, stranding as listed in the below table.
Insulation: Flexible extruded rubber insulation.
Jacket: Flexible cross-linked rubber jacket.
Application: This wire is constructed with a flexible insulation material covered with a flexible, yet durable jacket. Intended applications include military ground and vehicle supoort. Also, the cables are inherently flame resistant, and have excellent oil and fluid resistance.
| technical specification: | |
| conductor size awg | 6 |
|
conductor strands 30 awg strand size
|
259 |
| cold bending mandrel diameter (inches) | 1.75 |
|
conductor resistance
|
.459 |
|
ampacity rating ambient 25c-50c max.
|
145-120 |
| insulation diameter (inches) min. | .258 |
| insulation resistance (meg-ohms) | 250 |
| covering thickness (inches) min. avg. | .022 |
| covering diameter (inches) min. | .305 |
| covering diameter (inches) max. | .335 |
| rscc aerodefense part number | HTZR-6 |