General Cable TECK90® 3/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA

General Cable TECK90® 3/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA

Select gauge from drop-down menu for prices:

General Cable TECK90® 3/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA
TECK90 3/0 AWG 3 Conductor Three Power and Three 14 AWG Control Conductors XLPE PVC AIA PVC Power Control Composite 600V CSA

Conductor:
• 12 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8
• 6 AWG thru 4/0 AWG bare copper compact Class B strand

Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 14 AWG to 2 AWG—black, red and blue; 1 AWG to 4/0 AWG—printed numbers

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Aluminum Interlocked Armor (AIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands

Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances: CSA Standard C22.2 No. 131 and No. 174

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical speicfication
cond. size(AWG/kcmil) 3/0
no. of cond. 3
ground wire size (AWG) 4
min. avg. ins. thickness(inches) .055
min. avg. ins. thickness(mm) 1.40
nominal diameter (over)(insulation in inches) 0.58
nominal diameter (over)(insulation in mm) 17.1
nominal diameter (over)(armor in inches) 1.68
nominal diameter (over)(armor in mm) 42.5
nominal diameter (over)(cable in inches) 1.82
nominal diameter (over)(cable in mm) 46.1
copper weight(lbs/1000ft) 1753
copper weight(kg/km) 2609
net weight w/armor(lbs/1000ft in al) 2592
net weight w/armor(lbs/1000ft in steel) 3087
net weight w/armor(kg/km in al) 3857
net weight w/armor(kg/km in steel) 5740
ampacity** power cond. (30?c ambient) 225
catalog number 11288.215300*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question