Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and white; Triads - black, white and red. One conductor in each pair or triad is printed alphanumerically for easy identification

Shield:
Overall shielded pairs/triads: Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire

Jacket: Lead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Applications:
• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
• Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30?C
• Low-Smoke, Zero-Halogen jacket is environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire

Compliances:
Industry Compliances:
• UL 1277 Type TC-LS, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57
• ICEA T-33-655
• RoHS Compliant

Flame Test Compliances:
• UL 1581
• UL 1685 Vertical Flame Test
• IEEE 1202 Other

Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size (awg) 18
no. of pairs/triads 50
cond. strand 7W
minimum avg. insulation thickness(inches) 0.030
minimum avg. insulation thickness(mm) 0.76
minimum avg. jacket thickness(inches) 0.080
minimum avg. jacket thickness(mm) 2.03
nominal cable o.d.(inches) 2.570
nominal cable o.d.(mm) 65.28
copper weight(lbs/ 1000 ft) 523
copper weight(kg/km) 778
net weight(lbs/ 1000 ft) 1603
net weight(kg/km) 2386
catalog number 393810*