General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 20 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL

General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 20 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL

Select gauge from drop-down menu for prices:

General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 20 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
CHTC XLPE XL-CPE Type TC 18/20 Gauge Individual and Overall Shielded Pairs Triads Instrumentation Shielded 600V UL

Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and white; Triads - black, white and red. One conductor in each pair or triad is printed alphanumerically for easy identification

Shield:
Individual and overall shielded pairs/triads
• Individual pairs/triads are 100% shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire

Jacket: Lead-free Cross-linked Chlorinated Polyethylene (XL-CPE)

Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Oil-resistant jacket
• Sunlight- and weather-resistant
• Excellent electrical, thermal and physical properties
• Excellent moisture resistance
• Excellent flame resistance
• “Heavy duty” rating per ICEA standards
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 1277 Type TC, UL File # E57179
• UL 1581
• ICEA S-73-532/WC57
• RoHS Compliant

Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size (awg) 18
no. of pairs/ triads 20
cond. strand 7W
minimum avg. insulation thickness(inches) 0.030
minimum avg. insulation thickness(mm) 0.76
minimum avg. jacket thickness(inches) 0.080
minimum avg. jacket thickness(mm) 2.03
nominal cable o.d.(inches) 1.265
nominal cable o.d.(mm) 32.13
copper weight(lbs/ 1000 ft kg) 256
copper weight(kg/km) 381
net weight(lbs/ 1000 ft kg) 676
net weight(kg/km) 1006
catalog number 337680*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question