Helukabel 250 MCM 1 Core Green-Yellow Colour Single 600-J / -O Special Single Core Cable 600 V Meter Marking Copper Cable 10899

Helukabel 250 MCM 1 Core Green-Yellow Colour Single 600-J / -O Special Single Core Cable 600 V Meter Marking Copper Cable 10899

Select gauge from drop-down menu for prices:

Helukabel 250 MCM 1 Core Green-Yellow Colour Single 600-J / -O Special Single Core Cable 600 V Meter Marking Copper Cable 10899
Helukabel 250 MCM 1 Core Green-Yellow Colour Single 600-J / -O Special Single Core Cable 600 V Meter Marking Copper Cable 10899

Temperature Range:
• flexing -5°C bis +90°C
• fixed installation -40°C bis +90°C

Permissible Conductor Operating Temperature: +90°C

Nominal Voltage:
• VDE U0/U 600/1000 V
• UL/CSA 600 V

Test Voltage:
• 4000 V

Breakdown Voltage:
• min. 8000 V 

Minimum Bending Radius:
• flexing 7,5x cable Ø
• fixed installation 4x cable Ø

Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper, fine wire conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC to class 43, 90°C acc. to UL Std.1581 colour black or green-yellow
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 and class 43 acc. to UL Std.1581
• Sheath colour: black (RAL 9005)
• With meter marking

Properties:
• Chemical Resistance see "Technical Informations"
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV resistant

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B), UL VW-1, CSA FT1

Note:
• G = green-yellow x = black
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Screened analogue type: Single 600-CY-J / -O
• Also as 1000 V Style 10678 deliverable

Application:
• PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. These two norms approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines.
• = Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 250 MCM
no.cores x cross-sec. mm² 1 G 150
core colour green-yellow
outer ø app. - mm 25,0
cop. weight - kg/km 1440,0
weight app. - kg/km 1750,0
helukabel part number 10899