Helukabel 19 AWG 61 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13390

Helukabel 19 AWG 61 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13390

Select gauge from drop-down menu for prices:

Helukabel 19 AWG 61 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13390
Helukabel 19 AWG 61 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13390

Technical Data:
• Halogen-free flexible control cable adapted to DIN VDE 0285-525-3-11 / DIN EN 50525-3-11, to UL Style 20939, UL Std.758.

Temperature Range
• flexing -30°C to +80°C
• fixed installation -40°C to +80°C

Nominal Voltage
• U0/U 300/500 V
• UL/CSA 600 V

Test Voltage
• 3000 V

Minimum Bending Radius
• flexing 10x cable Ø
• fixed installation 4x cable Ø

Flexibility
• Alternate bending test acc. to DIN VDE 0473-396 / DIN EN 50396

Cable Structure:
• Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of halogen-free special polymer
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• Outer sheath of halogen-free special polymer
• Sheath colour: grey (RAL 7001) With meter marking
• LS0H= Low Smoke Zero Halogen

Properties:
• Highly flame retardant
• Resistant to oils and greases
• Resistant to UV and weathering
• Hydrolysis resistant
• Flexible, abrasion- and wear-resistant
• Ozone-resistant, recycleable
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Note:
• G = with GN-YE conductor x = without GN-YE conductor (OZ)
• Also available as a 0,6/1 kV cable Megaflex® 600
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Screened analogue type: Megaflex® 500-C

Application:
• For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.

technical specification:
awg-no. 19
no.cores x cross-sec.mm² 61 G 0,75
outer ø app. mm 20,9
cop. weight kg/km 439,0
weight app. kg/km 853,0
helukabel part number 13390

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question