Prysmian and Draka Cable 20 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-20-010X

Prysmian and Draka Cable 20 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-20-010X

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 20 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-20-010X
Prysmian and Draka Cable 20 Fiber Count Fire Resistant Single Mode Fiber Indoor and Outdoor halogen free loose tube Cable QFCI4-20-010X

Applications:
• Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel, petrol, glycol, ethanol, white spirit and ASTM oil 2.
• The resistance to these fluids is according to DOD-STD-1678, method 8030. The cable is reinforced with a steel wire braiding. The fibers are protected in gel-filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fiber and loose tube is color coded for easy identification during splicing and termination. The outer sheath is marked to show fiber type and cable type.

Cable Properties:

Tensile strength: (IEC 60794-1-2E1)
• Max tensile load during installation - 1500 N
• Max tensile load during operation - 500 N

Color Coding: (TIA/EIA-455-598C)

Crush: (IEC 60794-1-2E3 - 3000 N/10cm

Impact: (IEC 60794-1-2E4) - 20 impacts, 5J

Torsion: (IEC 60794-1-2E7) - ± 1 turn/1m

Cable bending:
• Minimum bending diameter - 250 mm
• Cable bend (IEC 60794-1-2E11) - < 0.1dB/ ±5 turn

Temperature window:
• Operation -30°C to +60°C
• Installation -10°C to +60°C
• Storage -40°C to +70°C

Chemical resistance:
• Mineral oils IRM 902 (IEC60811-2-1) - 7 days/23°C and 4 hours/70°C
• Diesel - IRM 903 (IEC60811-2-1) - 7 days/23°C and 4 hours/70°C

Fire and smoke classifications:
• IEC 60331-25 (750°C, 3 hours) - <1 dB excess loss
• Upgraded IEC 60331-25 (1000°C, 3 hours) - <1.5 dB excess loss
• BP-236
• IEC 61034
• IEC 60332-3 cat. A and C
• IEC 60754-1
• IEC 60754-2

technical specification:
number of fibers 20
number of fibers in each tube 4
number of tubes + fillers
5+1
loose tube diameter (mm) 2.2
outer diameter (mm) 14.3
weight (kg/km) 307
heat release (mj/km) 1201
prysmian and draka cable part number QFCI4-20-010X

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question