*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Belden 9890 Cable 20 AWG 10 Conductors Direct Burial Multi Conductor Overall Shield Solid HDPE Jacket Cable

Description:
• 20 AWG solid TC conductors, conductors cabled, polypropylene insulation, overall Beldfoil® shield (100% coverage), 22 AWG solid TC drain wire, HDPE jacket.

Insulation:
• Material: PP - Polypropylene
• Wall Thickness (mm): 0.3302

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: solid
• Material: TC - Tinned Copper

Outer Jacket:
• Material: HDPE - High Density Polyethylene
• Nom. Wall Thickness (mm): 1.016

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +80°C
• Bulk Cable Weight: 89.292 Kg/Km
• Max. Recommended Pulling Tension: 551.577 N
• Min. Bend Radius/Minor Axis: 82.550 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 75.463
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 137.802
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 34.4505
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 36.091
• Max. Operating Voltage - Non-UL: 350 V RMS
• Max. Recommended Current: 2.7 Amps/Conductor @ 25°C

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 20
# conductors 10
stranding solid
no. of conductors 10
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 7.874
belden cable part number 9890