Belden 9451P Cable 22 AWG Audio Single Pair Stranded 7x30 TC Plenum CMP FEP Insulation Cable

Belden 9451P Cable 22 AWG Audio Single Pair Stranded 7x30 TC Plenum CMP FEP Insulation Cable

Select gauge from drop-down menu for prices:

Belden 9451P Cable 22 AWG Audio Single Pair Stranded 7x30 TC Plenum CMP FEP Insulation Cable

Regular price $1,215.00 $810.00 Sale /per Foot

Belden 9451P Cable 22 AWG Audio Single Pair Stranded 7x30 TC Plenum CMP FEP Insulation Cable

Description:
• 22 AWG stranded (7x30) TC conductors, twisted pair, FEP insulation, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, Flamarrest® jacket.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1778

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC - Low Smoke Polyvinyl Chloride

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Tempeature Rating: 60°C
• Bulk Cable Weight: 20.835 Kg/Km
• Max. Recommended Pulling Tension: 120.101 N
• Min. Bend Radius/Minor Axis: 31.750 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.49215
• Nom. Capacitance Conductor to Conductor (pF/m): 114.835
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 219.827
• Nominal Velocity of Propagation (VP %): 69
• Nominal Delay (ns/m): 4.82307
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 46.9183
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 46.9183
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.9 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 9451

technical specification:
awg 22
# conductors -
stranding 7x30
no. of conductors 2
conductor material tinned copper
dia. (mm) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia, (mm.) 3.226
belden cable part number 9451P

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question