Belden 1213 Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor U/UTP-UnShielded Solid BC Flamarrest Jacket Cable

Belden 1213 Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor U/UTP-UnShielded Solid BC Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1213 Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor U/UTP-UnShielded Solid BC Flamarrest Jacket Cable
Belden 1213 Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor U/UTP-UnShielded Solid BC Flamarrest Jacket Cable

Description:
• CAT5e+ (350MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 24 AWG Solid Bare Copper Conductors, Dual FRPO/FEP Insulation, Ripcord, Flamarrest® Jacket.

Insulation:
• Material: FRPO/FEP - Flame Retardant Polyolefin/Fluorinated Ethylene Propylene

Outer Jacket:
• Trade Name: Flamarrest (R)
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.205
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422.

Mechanical Characteristics (Overall):
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 24 lbs/1000 ft.
• Max. Recommended Pulling Tension: 35 lbs.
• Min. Bend Radius/Minor Axis: 0.750 in.
• Min. Bend/Installation: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 5e - TIA 568.C.2
• Other Specification: NEMA WC-63.1 Category 5e

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 72.000
• Maximum Delay (ns/100 m): 510
• Max. Delay Skew (ns/100 m): 25
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 8.900
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C/(UL) Flame Test: FT6
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Aerial: No
• Suitability - Buiral: No
• Sunlight Resistance: No
• Oil Resistance: No
• Non-halogenated: No

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 1212

technical specification:
awg 24
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.205
belden cable part number 1213

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.