GENERAL CABLE Control Cable 12/30 Gauge 600V Multi-Conductor VW-1 UL Type TC-ER* ULTROL 60®+

GENERAL CABLE Control Cable 12/30 Gauge 600V Multi-Conductor VW-1 UL Type TC-ER* ULTROL 60®+

Select gauge from drop-down menu for prices:

GENERAL CABLE Control Cable 12/30 Gauge 600V Multi-Conductor VW-1 UL Type TC-ER* ULTROL 60®+

Product Details

Conductor: 14 AWG thru 10 AWG tinned annealed copper; Class B stranding; 2 thru 37 conductors

Insulation: 
• Flame-retardant, heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE) 
• Color code: Per ICEA Method 1, Table E-1

Jacket: Flame-retardant, moisture-, oil-, sunlightand radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) — Black 

Options:
• Conductor stranding 
• ISO Metric conductors 
• E-2 color code 

Applications:
• ULTROL® 60+ control cable is a 600 V multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating   stations and where flame retardancy is critical 
• For use in Class 1E power distribution and control circuits for power lighting, control and signal circuits 
• Can be installed in trays, conduit, ducts, or in direct burial applications 

Features: 
• Rated at 90˚C wet or dry 
• Fully traceable 
• Qualified for 60-year service life 
• Gamma and beta radiation resistant (up to 350 megarads) 
• Submergence operability 
• Long-term thermal endurance and superior electricals 
• Excellent mechanical cut-through properties 
• Long-term moisture and radiation stability 
• Free stripping for ease of termination 
• Meets cold bend test at -40°C 

Industry Compliances: 
• Class 1E Qualified in accordance with IEEE 323-1974/2003 and IEEE 383-1974/2003 
• ICEA S-73-532 
• UL 1277 Type TC-ER* 
• UL 44 XHHW-2 * -ER for > 2 conductors 

Flame Test Compliances: 
• IEEE 383:1974 
• IEEE 383:2003 
• ICEA T-29-520 
• IEEE 1202/FT4-1991, Aged & Unaged 
• VW-1 

Other: 
• Quality assurance program in accordance with NRC 10CFR50 Appendix B 
• ANSI N45.2 
• ASME NQA-1 
• NIAC 
• NUPIC 

Packaging: Material to be shipped on non-returnable wooden reels

technical specifications:
cond.size(awg) 12
no. of cond. 30
cond.strand 7/.0305
minimum avg.insulation thickness(inches)
0.030
minimum avg.insulation thickness(mm) 0.76
minimum avg.jacket thickness(inches) 0.080
minimum avg.jacket thickness(mm) 2.03
nominal cable o.d.(inches) 1.138
nominal cable o.d.(mm) 28.9
copper weight(lbs/1000 ft) 613
copper weight(kg/km) 912
net weight(lbs/1000 ft) 1058
net weight(kg/km) 1574
catalog number 27560.12.30