Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE/LSTPE/CWS/PO Flame Retardant and Instrumentation Cable 856833

Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE/LSTPE/CWS/PO Flame Retardant and Instrumentation Cable 856833

Select gauge from drop-down menu for prices:

Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE/LSTPE/CWS/PO Flame Retardant and Instrumentation Cable 856833
Draka Cable 2 Cores 10 Elements TFSI(c) 250V XLPE/LSTPE/CWS/PO Flame Retardant and Instrumentation Cable 856833

Construction: Annealed stranded circular copper, IEC 60228 class 2

Insulation: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)

Pair/Triple/Quad Twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner Covering: Flame retardant and halogen-free thermoplastic compound

Armour/Screen: Concentric copper conductor.

Outer Sheath: Flame retardant halogen-free thermoplastic compound, SHF1

Marking Text: "meter" "ar" DRAKA NORSK KABEL TFSI(c) 250V 16 PAIR 1.5 mm2 S105 IEC 60092-376 IEC 60332-1

Outer Sheath Colour: Grey or Blue

Core Identification Instrumentation Cables:
• Pair - Black-Light Blue
• Triple - Black-Light Blue-Brown
• Quad - Black-Light Blue-Brown-Grey

Operating Temperature: 90°C

Operating Voltage: 250V

Standards applied:
• IEC 60092-376 - Design
• IEC 60228 class 2 - Conductor
• IEC 60092-351 - Insulation
• IEC 60092-359 - Sheath
• IEC 60332-1 - Flame Retardant

Description:
• TFSI(C) 2PAIR 0.75mm2 S105
• TFSI(C) 2PAIR 0.75mm2 S105
• TFSI(C) 4PAIR 0.75mm2 S105
• TFSI(C) 4PAIR 0.75mm2 S105
• TFSI(C) 10PAIR 0.75mm2 S105
• TFSI(C) 10PAIR 0.75mm2 S105
• TFSI(C) 16PAIR 0.75mm2 S105
• TFSI(C) 16PAIR 0.75mm2 S105
• TFSI(C) 24PAIR 0.75mm2 S105
• TFSI(C) 24PAIR 0.75mm2 S105
• TFSI(C) 2TRIP 0.75mm2 S105
• TFSI(C) 2TRIP 0.75mm2 S105
• TFSI(C) 4TRIP 0.75mm2 S105
• TFSI(C) 4TRIP 0.75mm2 S105
• TFSI(C) 10TRIP 0.75mm2 S105
• TFSI(C) 10TRIP 0.75mm2 S105
• TFSI(C) 16TRIP 0.75mm2 S105
• TFSI(C) 16TRIP 0.75mm2 S105
• TFSI(C) 24TRIP 0.75mm2 S105
• TFSI(C) 24TRIP 0.75mm2 S105
• TFSI(C) 2PAIR 1.5mm2 S105
• TFSI(C) 2PAIR 1.5mm2 S105
• TFSI(C) 4PAIR 1.5mm2 S105
• TFSI(C) 4PAIR 1.5mm2 S105
• TFSI(C) 10PAIR 1.5mm2 S105
• TFSI(C) 10PAIR 1.5mm2 S105
• TFSI(C) 16PAIR 1.5mm2 S105
• TFSI(C) 16PAIR 1.5mm2 S105
• TFSI(C) 24PAIR 1.5mm2 S105
• TFSI(C) 24PAIR 1.5mm2 S105
• TFSI(C) 2TRIP 1.5mm2 S105
• TFSI(C) 2TRIP 1.5mm2 S105
• TFSI(C) 4TRIP 1.5mm2 S105
• TFSI(C) 4TRIP 1.5mm2 S105
• TFSI(C) 10TRIP 1.5mm2 S105
• TFSI(C) 10TRIP 1.5mm2 S105
• TFSI(C) 16TRIP 1.5mm2 S105
• TFSI(C) 16TRIP 1.5mm2 S105
• TFSI(C) 24TRIP 1.5mm2 S105
• TFSI(C) 24TRIP 1.5mm2 S105

Sheath Colour:
• GREY
• BLUE

Application: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.

technical specification:
no of cores in element 2
number of elements 10
cross section core, mm2 1.5
conductor diameter, mm 1.6
insulation thickness, mm 0.6
thickness bedding, mm 1.2
diameter bedding, mm 22.5 ± 1
wire diameter concentric conductor, mm 0.61
thickness outer sheath, mm 1.6
diameter outer sheath, mm 27 ± 1
weight of cable approx. (kg/km) 850
copper content approx. (kg/km) 342
draka cable part number 856833

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question