{"product_id":"ultraflex-liquid-tight-flexible-conduit","title":"Ultraflex Liquid Tight Flexible Conduit","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eRecognized component for use in protection of insulated wire in assemblies or consoles of electrical apparatus. Use is to be determined by Underwriters Laboratories Inc.\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003e\u003c\/strong\u003eNon-UL liquidtight raceway\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eType Non-UL, Ultraflex \u003cspan data-mce-fragment=\"1\"\u003eFlexible Conduit, \u003c\/span\u003eType SJT \u003cspan data-mce-fragment=\"1\"\u003eConduit\u003c\/span\u003e, Liquid Tight Conduit, PVC Jacket , Flexible Conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Ultraflex Liquid Tight Flexible Conduit is made with extra-flexible non-metallic tubing and corrugated flame resistant PVC. It is reinforced with a non-conductive black material for added mechanical protection, making it a trustworthy raceway component that meets UL standards.\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLIQUID-TUFF Liquid tight ULTRAFLEX MECHANICAL PROTECTION TUBING\/CONDUIT has a circular cross section with a smooth polyvinyl chloride (PVC) inner surface and an integral reinforcing member within the conduit wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Rating:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• 60°C Dry\u003cbr\u003e• 60°C Wet and oily\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReferences \u0026amp; Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eRecognized component Liquid tight Mechanical Protection\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eTubing under UL File Number E79977\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL1696 Standard for Non-Metallic Mechanical Protection Tubing\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCSA File LL69271\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCSA C22.2 No. 227.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhere applicable a separate grounding conductor is required for all trade sizes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarkings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe product marking is contained on the outer carton.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePerformance Tests:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe completed LIQUID-TUFF Liquid tight ULTRAFLEX TUBING and CONDUIT shall meet the performance requirements outlined below.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePerformance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eHeat Aging Test\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCold Bend Test\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eHeat Shock Test\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCrush Test\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eImpact Test\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eOil Spray Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCSA C22.3 No. 227.3\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL1696\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eNon-metallic Mechanical Protection Tubing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFile:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eUL E79977\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003e•\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eCSA 69271\u003c\/p\u003e","brand":"AFC Cable","offers":[{"title":"Default Title","offer_id":42479340879935,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/2_4b116473-e7a7-45f1-8ca9-065bb6c6795f.png?v=1761081777","url":"https:\/\/www.nassauelectrical.com\/products\/ultraflex-liquid-tight-flexible-conduit","provider":"NassauElectrical","version":"1.0","type":"link"}