Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840088

Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840088

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840088
Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6/1kV Power and Control or Lighting Cable 840088

Conductor: Tinned Standed circular copper, BS 6360, class 2

Insulation: EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding: Cores laid up in concentric layers

Inner covering: Flame retardant and halogen-free thermoset compound

Tape over inner covering: PET tape + rubberized Polyamide tape

Armour/screen: Galvanized steel wire braid

Tape over armour/screen: PET tape + rubberized Polyamide tape

Outer sheath: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text: "meter mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour: Black

Core identification: All cores are offwhite with black numbers No 1,2,3.....

Operating temperature: 90°C

Operating Voltage: 0.6/1kV

Standards applied:
• BS6883 / UKOOA - Design
• BS6360 class 2 - Conductor
• BS7655 section 1.2 - Insulation
• BS7655 section 2.6 - Sheath
• IEC 60332-1 - Flame Retardant
• IEC60332-3-22 - Flame retardant
• IEC60754-1.2 - Halogen Free
• IEC 61034-1.2 - Low Smoke

Description:
• RFCU 0.6/1kV 2X 1.5mm2
• RFCU 0.6/1kV 2X 2.5mm2
• RFCU 0.6/1kV 2X 4mm2
• RFCU 0.6/1kV 2X 6mm2
• RFCU 0.6/1kV 2X 16mm2
• RFCU 0.6/1kV 2X 35mm2
• RFCU 0.6/1kV 3X 1.5mm2
• RFCU 0.6/1kV 3X 2.5mm2
• RFCU 0.6/1kV 3X 4mm2
• RFCU 0.6/1kV 3X 6mm2
• RFCU 0.6/1kV 3X 10mm2
• RFCU 0.6/1kV 3X 16mm2
• RFCU 0.6/1kV 3X 25mm2
• RFCU 0.6/1kV 3X 35mm2
• RFCU 0.6/1kV 3X 50mm2
• RFCU 0.6/1kV 3X 70mm2
• RFCU 0.6/1kV 3X 95mm2
• RFCU 0.6/1kV 4X 1.5mm2
• RFCU 0.6/1kV 4X 2.5mm2
• RFCU 0.6/1kV 4X 4mm2
• RFCU 0.6/1kV 4X 6mm2
• RFCU 0.6/1kV 4X 10mm2
• RFCU 0.6/1kV 4X 16mm2
• RFCU 0.6/1kV 4X 25mm2
• RFCU 0.6/1kV 4X 35mm2
• RFCU 0.6/1kV 4X 50mm2
• RFCU 0.6/1kV 4X 70mm2
• RFCU 0.6/1kV 4X 95mm2
• RFCU 0.6/1kV 5X 1.5mm2
• RFCU 0.6/1kV 7X 1.5mm2
• RFCU 0.6/1kV 7X 2.5mm2
• RFCU 0.6/1kV 12X 1.5mm2
• RFCU 0.6/1kV 12X 2.5mm2
• RFCU 0.6/1kV 19X 1.5mm2
• RFCU 0.6/1kV 19X 2.5mm2
• RFCU 0.6/1kV 27X 2.5mm2
• RFCU 0.6/1kV 37X 2.5mm2

Sheath Colour: BLACK

Design standard:
• BS 6883 : 1999
• BS 6883 : 1991

Application:
• Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.
• Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

technical specification:
number of cores 4
cross section core, mm2 70
conductor diameter, mm 10.85
insulation thickness, mm 1.4
thickness inner sheath, mm 2.1
approx. diameter inner sheath, mm 38
diameter braid wire, mm 0.45
thickness outer sheath, mm 2.4
approx. overall diameter, mm 44
weight of cable approx. (kg/km) 4670
copper content approx. (kg/km) 2484
ukooa code wb470
prysmian and draka cable part number 840088

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question