Draka Cable 262 MCM Bostrig MHV3-5(LS) Three Conductor Power Type L Jacket 5kV Shielded 100% or 133% Level Unarmored Cable

Draka Cable 262 MCM Bostrig MHV3-5(LS) Three Conductor Power Type L Jacket 5kV Shielded 100% or 133% Level Unarmored Cable

Select gauge from drop-down menu for prices:

Draka Cable 262 MCM Bostrig MHV3-5(LS) Three Conductor Power Type L Jacket 5kV Shielded 100% or 133% Level Unarmored Cable
Draka Cable 262 MCM Bostrig MHV3-5(LS) Three Conductor Power Type L Jacket 5kV Shielded 100% or 133% Level Unarmored Cable

Conductor:
• Soft annealed tinned copper.
• Stranding as shown in table below.

Conductor Shield: Semi-conducting tape with extruded thermosetting semi-conducting EPR.

Insulation:
• Extruded thermosetting EPR, 90C-Type E.
• Thickness as shown in table below.

Insulation Shield: Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield: Tinned copper braided shield, 85% minimum coverage.

Jacket:
• A jacket of flame retardant, Low Smoke Zero Halogen chemically crosslinked polyolefin (XLPO) is applied over the cabled core.
• Thickness as shown in table below.

Tests: Meets applicable test requirements in IEC 60502, IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-112, and flame test in IEC 332-3, cat A, A/F.

Rating:
• Listed by a Nationally Recognized Testing Lab (NRTL) in conformance to IEC 60502, UL 1072, and ICEA S-68-516. Cable also meets the performance requirements of IEEE 45-1998 & 1993 (draft).
• Type approved by DNV, ABS and LRS.

Application:
• Bostrig MHV3-5(LS) three conductor 5,000 volt shielded cables are suitable for use in commercial marine applications, MODU's, and platforms where flame retardant cables having excellent physical and electrical properties are required. The cables have excellent resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.
• Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor evenlyl distributed in the interstices.

technical specification:
conductor size awg/mcm 262
conductor size mm² 133.0
conductor size stranding 650/24
biw cable type mhv3-5(ls)-262
insulation wall thickness (inches) .095
insulation wall thickness (mm) 2.40
jacket wall thickness (inches) .125
jacket wall thickness (mm) 3.18
cable diameter (inches) 2.520
cable diameter (mm) 64.01
approx.weight (lbs/m') 4500
approx.weight (kg/km) 6697

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question