Conductor: Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. 

Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. 

Armor: Braided bronze in accordance with IEEE 1580. 

Sheath: Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.

Applications: 
• Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. 
• This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. 
• This product can also be manufactured in an unarmored version. 
• Multiconductor power, control, and instrumentation cables are also available. 

Features/Ratings:
• Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact 
• High strand count conductors provide superior flexibility 
• Higher allowable conductor operating temperature results in increased ampacity 
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3 
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A 
• Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6/1kV 
• This product may be manufactured in an unarmored or armored and sheathed version 
• Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore 
• Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore 

Approvals:
• IEEE 1580 and IEEE 45- Marine Shipboard Cable 
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110 
• Det Norske Veritas (DNV) 
• American Bureau of Shipping (ABS) 
• Transport Canada Approved AMS400-20-2 
• Transport Canada 8700-20-2 
• Lloyd’s Register of Shipping (LRS) 
• United States Coast Guard-46CFR

technical specification:
conductor size awg/mcm 646
conductor size mm² 327.5
sheath thickness in 0.080
sheath thickness mm 2.0
cable diameter (nominal) in
1.530
cable diameter (nominal) mm
38.9
impedance (phase-neutral) ω/kft
0.04
impedance (phase-neutral) ω/km 0.1
inductance (mh/kft) 0.10
inductance (mh/km) 0.3
capacitance (pf/ft) 216
capacitance (pf/m) 708
ampacity (measured @ 95ºc)
670
ampacity (measured @ 100ºc) 731
ampacity (measured @110ºc) 783
ampacity (measured @ 125ºc)
979
cable weight approximate (lbs/mft) 2,790
cable weight approximate (kg/km) 4,150
type designation SPM2KV(HD)-646