{"product_id":"type-mp-gc-500mcm-25kv-three-conductor-epr-cpe","title":"General Cable Type MP-GC® 500MCM 25kv Three Conductor EPR CPE","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy Our TYPE MP-GC 500MCM 25KV THREE CONDUCTOR EPR CPE. Provides High-Voltage Distribution Intended for Permanent Installations.\"\u003e\u003cmeta name=\"Keywords\" content=\"Mining Cable, 500MCM TYPE MP-GC Cable, 500MCM Mine Power Feeder Cable, 500MCM MP-GC Feeder Cable, 500MCM MP-GC EPR Cable, 500MCM Anaconda Brand Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda Brand Type MP-GC (Uniblend EPR) Mine Power Feeder W\/Ground-Check EPR CPE 25000 Volts Three Conductor cables are three-conductor cables that include two neutral ground conductors and a ground check conductor.  The cable conductive components are made of Class B, coated, rope-lay-stranded, annealed copper wires.  The annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties.  The annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR); a synthetic rubber that is resistant to sunlight, moisture, and oil.  The ground-check conductor is insulated with yellow polypropylene.  An extruded strand shield is applied directly over each insulated conductor.  An extruded insulation shield covers the assembly of conductors.  The insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.  The shield serves to prevent leakage and electrical shock.  The cable gets most of its strength from its extra heavy-duty exterior jacket.  The CPE jacket is a layer of lead-cured, chlorinated polyethylene.  This material is resistant to oils, chemicals, high or low temperatures, and weather.  CPE jacketed cables are also flame retardant and have great tensile strength.  The jacket helps with the cable’s overall resistance to crushing, abrasion, and cut-through.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnaconda Brand Type MP-GC (Uniblend EPR) Mine Power Feeder W\/Ground-Check EPR CPE 25000 Volts Three Conductor holds a temperature rating of -40°C to 90°C.  The cable is primarily used in light to medium-duty mining applications because of its durable yet flexible construction.  The cable can be used for heavy-duty tasks such as power supply cable, power cable for portable and mobile electric equipment, motors, and industrial appliances.  The cable can also be used in construction zones or locations with a high chance of vehicle run-over.  The cable passes FT-5 flame test and aligns with UL 1650, deeming the cable suitable for use in locations with an increased risk of fire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, a compliance and regulations organization established over 100 years ago, the cable aligns with ASTM standard B172, a standard for rope-lay-stranded conductors.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe Pennsylvania Department of Environmental Protection approves this cable.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable meets CAN\/CSA C22.2 No. 96.1 Mine Power Feeder Cables.\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe cable is compliant with Mining Safety and Health Administration requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable features two coated, rope-lay-stranded, annealed copper wire conductors.\u003c\/li\u003e\n\u003cli\u003eThe cable uses coated, rope-lay-stranded, annealed copper wires.\u003c\/li\u003e\n\u003cli\u003eThe annealed copper product used in this cable offers superior flexibility compared to standard copper, but offers the same powerful conductive properties. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a coated copper, rope-lay-stranded ground conductor.\u003c\/li\u003e\n\u003cli\u003eThe ground conductor serves to ensure steady conductivity through the phase conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGround-Check Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe ground-check conductor is composed of Class B, coated, rope-lay-stranded, annealed copper.\u003c\/li\u003e\n\u003cli\u003eThe ground-check conductor is insulated with yellow polypropylene.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe annealed copper phase conductors and the neutral ground conductor are insulated with ethylene propylene rubber (EPR).\u003c\/li\u003e\n\u003cli\u003eEPR is a synthetic rubber that is resistant to sunlight, moisture, and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eExtruded Insulation Shield\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation shield is made of thermoset, semi-conductive material wrapped in copper tape.\u003c\/li\u003e\n\u003cli\u003eThe shield serves to prevent leakage and electrical shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe cable’s jacket is a layer of lead-cured, chlorinated polyethylene (CPE).\u003c\/li\u003e\n\u003cli\u003eThis material is resistant to oils, chemicals, high or low temperatures, and weather.\u003c\/li\u003e\n\u003cli\u003eThe jacket adds tensile strength to the cable and also helps with the cable’s resistance to crushing, abrasion, and cut-through.\u003c\/li\u003e\n\u003cli\u003eThe jacket comes standard in black but is available in colors if specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg\/kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd.cond.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003egrd-check cond. size(awg)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal cable 0.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable 0.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e87.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e9541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enet weight(lbs\/1000 ft)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e15328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003e536\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e16367.916500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163491483711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_24f15aa0-a6f1-4115-b0ab-448b97a842be.jpg?v=1571728229","url":"https:\/\/www.nassauelectrical.com\/products\/type-mp-gc-500mcm-25kv-three-conductor-epr-cpe","provider":"NassauElectrical","version":"1.0","type":"link"}