{"product_id":"superior-essex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1","title":"Superior Essex Cable 36 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4036ZZB1","description":"\n    \n        \u003ctitle\u003eSuperiorEssex Cable 36 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4036ZZB1\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of SuperiorEssex Cable 36 Fiber Count Base-12 2mm Microarray Breakout OFNP Cable V4036ZZB1. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"SuperiorEssex Cable, 36  Fiber Count Base-12, 2 mm Microarray Cable, Breakout OFNP Cable, SuperiorEssex Cable Price, 36 Fiber Count Base-12, 2 mm Microarray Cable Price, Breakout OFNP Cable Price, SuperiorEssex Cable Quote, 36  Fiber Count Base-12, 2 mm Microarray Cable Quote, Breakout OFNP Cable Quote V4036ZZB1.\"\u003e\n    \n    \n        \u003cp\u003eThe 2 mm Microarray Breakout cable from Superior Essex is designed\n        for high performance in a small package. The premises loose tube design\n        consists of 8 or 12-fiber 2 mm microarray interconnect cable subunits,\n        each of which contain twelve 250 micron fibers. The aramid yarns inside\n        the subunit allow the subunit to be crimped directly onto an MTP®\/\n        MPO connector. The 2 mm subunits are stranded around a central\n        strength element that is both flexible and robust enough to pass backbone\n        installation requirements. The stranded subunits are held to the strength\n        element core by binder yarns and\/or tapes ensuring excellent temperature\n        performance. Finally, a RoHS-compliant flexible jacket protects the core\n        from the rigors of installation while providing plenum fire protection. The\n        cable is available with TeraFlex® single mode, and TeraFlex laser-optimized\n        50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4)\n        multimode fiber types.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e\n        • UL® Certified Environmental \u003cbr\u003e\n        • Health Product Declaration\u0026amp;trade\n        (HPD™)\u003cbr\u003e\n        • 8 or 12-fiber 2 mm loose tube\n        interconnect subunits\u003cbr\u003e\n        • Meets or exceeds\n        ICEA 83-596-2001 and\n        GR-409-CORE requirements\n        for interconnect subunits and\n        trunk cable\u003cbr\u003e\n        • Plenum (OFNP) rated design \u003cbr\u003e\n        • Available with TeraFlex single\n        mode, and TeraFlex laseroptimized\n        50\/125 micron\n        multimode fiber types\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e\n        • Contributes toward 1 LEED\n        point under the Material and\n        Resources credit (MRc)\u003cbr\u003e\n        • Contributes toward 1 LEED\n        point under the MRc\u003cbr\u003e\n        • Connects directly to MTP\/MPO\n        12-fiber array connectors\u003cbr\u003e\n        • Worry-free installation\n        and performance\u003cbr\u003e\n        • Meets NEC requirements\u003cbr\u003e\n        • Build your network with the fiber\n        type that you need now or for\n        the future\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n        \u003cstrong\u003eSubunit Configuration - \u003c\/strong\u003e2 mm Simplex loose tube cable with\n        eight or twelve 250 micron optical\n        fibers surrounded by dielectric\n        aramid strength members\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Configuration - \u003c\/strong\u003e2 mm loose tube subunits around\n        a central strength member and\n        surrounded by polyester yarns and\n        an outer jacket\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSubunit Marking - \u003c\/strong\u003eUnit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCentral Strength Element - \u003c\/strong\u003eGlass Reinforced Plastic (GRP)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket - \u003c\/strong\u003eFlame retardant, thermoplastic\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePerformance Compliance\u003c\/strong\u003e\u003cbr\u003e\n        • UL 1651\u003cbr\u003e\n        • CSA C22.2 No. 232\u003cbr\u003e\n        • NFPA 262\u003cbr\u003e\n        • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e\n        • ANSI\/ICEA S-83-596\u003cbr\u003e\n        • ANSI\/TIA-568-C.3\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNRTL Programs\u003c\/strong\u003e\u003cbr\u003e\n        • UL, c(UL) Listed OFNP\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSustainability\u003c\/strong\u003e\u003cbr\u003e\n        • UL Certified EPD\u003cbr\u003e\n        • HPD\u003cbr\u003e\n        • USGBC® Member\u003cbr\u003e\n        • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e\n        • REACH-compliant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003e\n        • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e\n        • Data centers\u003cbr\u003e\n        • Trunk applications\u003cbr\u003e\n        • High density installations\u003cbr\u003e\n        • MTP\/MPO array connectors\u003cbr\u003e\n        • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003eTechnical Specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eFiber Count\u003c\/td\u003e\n                    \u003ctd\u003e36\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eCable Configuration\u003c\/td\u003e\n                    \u003ctd\u003e4-around-1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Diameter\n                    in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.26 (6.5)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eNominal Weight\n                    lbs\/kft (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e29 (43)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMaximum Tensile Loading Install\n                    lbs (n)\u003c\/td\u003e\n                    \u003ctd\u003e150 (660)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMaximum Tensile Loading Long Term\n                    lbs (n)\u003c\/td\u003e\n                    \u003ctd\u003e45 (200)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bend Radius Install\n                    in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.8 (98)\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eMinimum Bend Radius Long Term\n                    in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.6 (65)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ePackage\u003c\/td\u003e\n                    \u003ctd\u003eplywood reel\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eListing\u003c\/td\u003e\n                    \u003ctd\u003eOFNP\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eSuperiorEssex Cable Part Number\u003c\/td\u003e\n                    \u003ctd\u003eV4036ZZB1\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164989276223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/2_20mm_20Microarray_20Breakout-lg_b2aaaadf-21d5-4af2-9f30-51f76554c0da.jpg?v=1571728590","url":"https:\/\/www.nassauelectrical.com\/products\/superior-essex-cable-36-fiber-count-base-12-2mm-microarray-breakout-ofnp-cable-v4036zzb1","provider":"NassauElectrical","version":"1.0","type":"link"}