{"product_id":"superior-essex-cable-24-fiber-count-base-12-3mm-microarray-breakout-ofnr-cable-p3024zzb1","title":"Superior Essex Cable 24 Fiber Count BASE-12 3mm Microarray Breakout OFNR Cable P3024zzB1","description":"\n    \n        \u003ctitle\u003eSuperior Essex Cable 24 Fiber Count BASE-12 3mm Microarray Breakout OFNR Cable P3024zzB1\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 24 Fiber Count BASE-12 3mm Microarray Breakout OFNR Cable P3024zzB1. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Superior Essex Cable, 3mm Cable, Microarray Cable, Microarray Breakout Cable, OFNR Cable, OFNP Cable, Superior Essex Cable Price, 3mm Cable Price, Microarray Cable Price, Microarray Breakout Cable Price, OFNR Cable Price, OFNP Cable Price, Superior Essex Cable Quote, 3mm Cable Quote, Microarray Cable Quote, Microarray Breakout Cable Quote, OFNR Cable Quote, OFNP Cable Quote, 24 Fiber Count BASE-12 Cable, P3024zzB1\"\u003e\n    \n    \n        \u003cp\u003eThe 3 mm Microarray Breakout cable from Superior Essex is designed for high performance in a small package. The premises loose tube design consists of 3 mm microarray interconnect cable subunits, each of which contain either eight or twelve 250 micron fibers. The aramid yarns inside the subunit allow the subunit to be crimped directly onto an MTP®\/MPO connector. The 3 mm subunits are stranded around a central strength element that is both flexible and robust enough to pass backbone installation requirements. The stranded subunits are held to the strength element core by binder yarns and\/or tapes ensuring excellent temperature performance. Finally, a RoHS-compliant flexible jacket protects the core from the rigors of installation while providing riser or plenum fire protection. The cable is available with TeraFlex® single mode, and laser-optimized 50\/125 micron 10G\/150 (OM2+), 10G\/300 (OM3) and 10G\/550 (OM4) multimode fiber types.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\n        • UL® Certified Environmental Product Declaration (EPD)\u003cbr\u003e\n        • Health Product Declaration™ (HPD™)\u003cbr\u003e\n        • 8 or 12-fiber 3 mm loose tube interconnect subunits\u003cbr\u003e\n        • Meets or exceeds ICEA 83-596-2001 and GR-409-CORE requirements for interconnect subunits and trunk cable\u003cbr\u003e\n        • Plenum (OFNP) and riser (OFNR) rated designs\u003cbr\u003e\n        • Available with TeraFlex single mode, and laser-optimized 50\/125 micron multimode fiber types\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBenefits:\u003c\/strong\u003e\u003cbr\u003e\n        • Contributes toward 1 LEED point under the Material and Resources credit (MRc)\u003cbr\u003e\n        • Contributes toward 1 LEED point under the MRc\u003cbr\u003e\n        • Connects directly to MTP\/MPO 12-fiber array connectors\u003cbr\u003e\n        • Worry-free installation and performance\u003cbr\u003e\n        • UL listed cables meet NEC requirements\u003cbr\u003e\n        • Build your network with the fiber type that you need now or for the future\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e\n        \u003cstrong\u003eSubunit Configuration:\u003c\/strong\u003e\u003cbr\u003e\n        3 mm Simplex loose tube cable with eight or twelve 250 micron optical fibers surrounded by dielectric aramid strength members\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Configuration:\u003c\/strong\u003e\u003cbr\u003e\n        3 mm loose tube subunits around a central strength member and surrounded by polyester yarns and an outer jacket\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSubunit Marking:\u003c\/strong\u003e\u003cbr\u003e\n        Unit 1, Unit 2, Unit 3, Unit 4...\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCentral Strength Element:\u003c\/strong\u003e\u003cbr\u003e\n        Glass Reinforced Plastic (GRP) covered with a PVC jacket\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSubunit\/Outer Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        • OFNR: Flame retardant (FR) PVC\u003cbr\u003e\n        • OFNP: FR, low smoke PVC\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePerformance Compliance:\u003c\/strong\u003e\u003cbr\u003e\n        • UL 1651\u003cbr\u003e\n        • CSA C22.2 No. 232\u003cbr\u003e\n        • UL 1666\u003cbr\u003e\n        • NFPA 262\u003cbr\u003e\n        • Telcordia® GR-409-CORE, Issue 2\u003cbr\u003e\n        • ANSI\/ICEA S-83-596\u003cbr\u003e\n        • ANSI\/TIA-568-C.3\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNRTL Programs:\u003c\/strong\u003e\u003cbr\u003e\n        • UL, c(UL) Listed OFNR\u003cbr\u003e\n        • UL, c(UL) Listed OFNP\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSustainability:\u003c\/strong\u003e\u003cbr\u003e\n        • UL Certified EPD\u003cbr\u003e\n        • HPD\u003cbr\u003e\n        • USGBC® Member\u003cbr\u003e\n        • RoHS-compliant\/RoHS 2-compliant\u003cbr\u003e\n        • REACH-compliant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\n        • 10 Gb, 40 Gb, 100 Gb Ethernet and legacy speeds\u003cbr\u003e\n        • Data centers\u003cbr\u003e\n        • Trunk applications\u003cbr\u003e\n        • High density installations\u003cbr\u003e\n        • MTP\/MPO array connectors\u003cbr\u003e\n        • Outside plant (OSP) to premises transitions\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003efiber count\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003elisting\u003c\/td\u003e\n                    \u003ctd\u003eOFNR\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable configuration\u003c\/td\u003e\n                    \u003ctd\u003e4-around-1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal diameter in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.42 (10.8)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal weight lbs\/kft (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e60 (90)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emaximum tensile loading install lbs (n)\u003c\/td\u003e\n                    \u003ctd\u003e150 (710)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emaximum tensile loading long term lbs (n)\u003c\/td\u003e\n                    \u003ctd\u003e45 (198)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bend radius install in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.0 (180)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bend radius long term in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.5 (90)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003epackage\u003c\/td\u003e\n                    \u003ctd\u003ePlywood Reel\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n                    \u003ctd\u003eP3024zzB1\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164911157311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/3_20mm_20Microarray-lg_5d302450-5e17-4023-9c8b-a2ceee1bc2e1.jpg?v=1571728565","url":"https:\/\/www.nassauelectrical.com\/products\/superior-essex-cable-24-fiber-count-base-12-3mm-microarray-breakout-ofnr-cable-p3024zzb1","provider":"NassauElectrical","version":"1.0","type":"link"}