{"product_id":"superior-essex-cable-1-0-awg-epr-cts-tp-cpe-power-type-mv-25kv-copper-unfilled-cdr-25kv-100-i-l-260-mils-shielded-cable-e8kme-1a1b01ca00","title":"Superior Essex Cable 1\/0 AWG EPR\/CTS\/TP-CPE Power Type MV- 25kV Copper Unfilled Cdr 25kV 100% I.L.260-mils Shielded Cable E8KME-1A1B01CA00","description":"\n    \n        \u003ctitle\u003eSuperior Essex Cable 1\/0 AWG EPR\/CTS\/TP-CPE Power Type MV- 25kV Copper Unfilled Cdr 25kV 100% I.L.260-mils Shielded Cable E8KME-1A1B01CA00\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 1\/0 AWG  Cable, Superior Essex Cable ,Superior Essex Cable EPR\/CTS\/TP-CPE Power Cable,Superior Essex Cable EPR\/CTS\/TP-CPE Power  Price,Power Type MV-105,5kV-35kV Cable,Power Type MV-105,5kV-35kV Quote,EPR\/CTS\/TP-CPE Power Type MV-105,5kV-35kV Copper Conductors Cable, EPR\/CTS\/TP-CPE Power Type MV-105,5kV-35kV Copper Conductors Cable Price, EPR\/CTS\/TP-CPE Power Type MV-105,5kV-35kV Copper Conductors Cable Quote.\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 1\/0 AWG EPR\/CTS\/TP-CPE Power Type MV- 25kV Copper Unfilled Cdr 25kV 100% I.L.260-mils Shielded Cable E8KME-1A1B01CA00 Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003eThe Superior Essex Medium Voltage, EPR\/Cu Tape Shield\/CPE, Type MV-105\n        Cable consist of fully annealed bare copper Class B stranded conductors,\n        covered with ethylene propylene rubber (EPR), copper tape shield, and black\n        CPE jacket. These cables are used in industrial power circuits.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\n        • Rated at 105°C wet or dry\u003cbr\u003e\n        • Excellent corona resistance\u003cbr\u003e\n        • High dielectric strength\u003cbr\u003e\n        • Low moisture absorption\u003cbr\u003e\n        • Low dielectric loss\u003cbr\u003e\n        • Excellent sunlight resistance\u003cbr\u003e\n        • For CT USE for 1\/0 AWG and larger, per UL® 1072\u003cbr\u003e\n        • Meets cold bend test at -35°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e\n        \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eFull annealed bare copper Class B compressed strand\n        (filled or unfilled)\n        Also available with copper Class B compact strand\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003eFilled: Available in 2 AWG through 1000 kcmil\n        Unfilled: Available in 2 AWG through 1000 kcmil\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor\n        Strand Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over\n        the conductor\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eShield: \u003c\/strong\u003e5 mil annealed copper tape helically applied with a\n        25% overlap\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eThermoplastic Chlorinated Polyethylene (TP-CPE)\u003c\/p\u003e\n        \u003cstrong\u003eJacket Marking: \u003c\/strong\u003e\u003cbr\u003e\n        \u003cp\u003e\u003cstrong\u003e2 AWG – 1 AWG: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG 1\/C\n        XXKV XXX% INSUL LEVEL XXXMILS EPR\/PVC JKT TYPE\n        MV-105 SUN RES (UL) MADE IN USA MMDDYYYY\n        (LIGHTNING BOLT)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003e1\/0 AWG – 1000 kcmil: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG\n        (or XXXKCMIL) 1\/C XXKV XXX% INSUL LEVEL XXXMILS\n        EPR\/PVC JKT TYPE MV-105 FOR CT USE (UL) SUN RES\n        MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths\n        and dimensions\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e\n        • ASTM B8\u003cbr\u003e\n        • UL 1072, UL 1685 (flame compliance)\u003cbr\u003e\n        • ICEA S-93-639\/NEMA WC74, ICEA S-97-682\u003cbr\u003e\n        • AEIC CS8\u003cbr\u003e\n        • NEC\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Compliances: \u003c\/strong\u003e\u003cbr\u003e\n        • EPA 40 CFR, Part 261\u003cbr\u003e\n        • OSHA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e\n        • In conduit, duct, free air, and raceways, primary installations include\n        cable trays, and outdoor locations\u003cbr\u003e\n        • In direct burial if installed in a system with a ground conductor that is\n        in close proximity, and conforms with  NEC 250.4 (A)(5)\u003cbr\u003e\n        • In wet or dry locations\u003cbr\u003e\n        • Approved for Class I, Div. 2 industrial hazardous locations per NEC\u003cbr\u003e\n        • Designed to operate continuously at a conductor temperature\n        not exceeding\u003cbr\u003e\n        •  105°C for normal operations\u003cbr\u003e\n        • 140°C for emergency overload\u003cbr\u003e\n        •  250°C for short circuit\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e\n        Also Available in:\u003cbr\u003e\n        • Copper Unfilled Cdr 5kV 133%\/8kV 100% I.L., 115-mils, Shielded Series E8FME\u003cbr\u003e\n        • Copper Unfilled Cdr 15kV 133% I.L., 220-mils, Shielded Series E8JME\u003cbr\u003e\n        • Copper Unfilled Cdr 25kV 133% I.L., 320-mils, Shielded Series E8LME\u003cbr\u003e\n        • Copper Unfilled Cdr 35kV 133% I.L., 420-mils, Shielded Series E8NME\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n                    \u003ctd\u003e1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003enominal conductor diameter¹ in (mm)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.358 (9.1)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.952 (24.18)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.080 (2.03)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.231 (31.3)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e995 (1,481)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (conduit in air²)\u003c\/td\u003e\n                    \u003ctd\u003e215\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (underground duct³)\u003c\/td\u003e\n                    \u003ctd\u003e215\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n                    \u003ctd\u003eE8KME-1A1B01CA00\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Superior Essex Cable","offers":[{"title":"Default Title","offer_id":7166064361535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Type_20MV-105_205kV_E2_80_9335kV-372-LG_3040e327-b506-44f8-83a8-da56fbb1a8f3.jpg?v=1571728779","url":"https:\/\/www.nassauelectrical.com\/products\/superior-essex-cable-1-0-awg-epr-cts-tp-cpe-power-type-mv-25kv-copper-unfilled-cdr-25kv-100-i-l-260-mils-shielded-cable-e8kme-1a1b01ca00","provider":"NassauElectrical","version":"1.0","type":"link"}