{"product_id":"prysmian-cable-4-0-awg-35kv-100-copper-trxlpe-urd-csa-single-phase-full-neutral-medium-voltage-utility-cables-qbb01zc","title":"Prysmian Cable 4\/0 AWG 35kV 100% Copper TRXLPE URD CSA Single Phase Full Neutral Medium Voltage Utility Cables QBB01ZC","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG 35kV 100% Copper TRXLPE URD CSA Single Phase Full Neutral Medium Voltage Utility Cables QBB01ZC\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG 35kV 100% Copper TRXLPE URD CSA Single Phase Full Neutral Medium Voltage Utility Cables QBB01ZC. Click for a free quote. 4\/0 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable QBB01ZC, 4\/0 AWG 35kV 100% Copper TRXLPE URD CSA Single Phase Full Neutral Medium Voltage Utility Cables QBB01ZC, QBB01ZC, TRXLPE URD CSA Cable, CSA Cable, Medium Voltage Utility Cables, TRXLPE Insulation Cable, LLDPE Jacket Cable, Aluminum Single Conductor Cable, Copper  Single Conductor Cable, URD Cable, TRXLPE URD Cable, Underground Residential Cable, 35kV 100% Copper TRXLPE URD CSA Medium Voltage Utility Cables\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Solid or Class B compact or compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Natural high dielectric strength VOLTENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield\u003c\/strong\u003e: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield\u003c\/strong\u003e: Solid bare copper wires, helically applied and uniformly spaced.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e:\u003cbr\u003e\n        • Black LLDPE jacket with no stripes\u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape\u003cbr\u003e\n        • No Jacket\u003cbr\u003e\n        • EPROTENAX™ (EPR) insulation\u003cbr\u003e\n        • Multiplex cables\u003cbr\u003e\n        • Tinned round and flat strap neutrals\u003cbr\u003e\n        • Strandseal®\u003cbr\u003e\n        • Super smooth conductor shield\u003cbr\u003e\n        • Cables made to AEIC CS8 and\/or ICEA S-94-649\u003cbr\u003e\n        • 46kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallations\u003c\/strong\u003e:\u003cbr\u003e\n        • Conduit in Air\u003cbr\u003e\n        • Direct Buried\u003cbr\u003e\n        • Underground Duct\u003cbr\u003e\n        • Isolated in Air\u003cbr\u003e\n        • Wet Locations\u003cbr\u003e\n        • Dry Locations\u003cbr\u003e\n        • With Messenger\u003cbr\u003e\n        • Utility Primary\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and Ratings\u003c\/strong\u003e:\u003cbr\u003e\n        • CSA - CSA C68.5 -40°C\u003cbr\u003e\n        • For 90°C continuous, 130°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 awg cu\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e345\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e32-#12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e12.14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e31.19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e33.53\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e40.48\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e2962\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e330\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e319\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e0.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e0.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)†† - 90°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e402\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e0.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e0.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQBB01ZC\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186430427199,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5-46kV_20TRXLPE_20URD_20CSA-lg_cafb6005-681b-4335-9e8f-4664a335f73b.jpg?v=1571729053","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-cable-4-0-awg-35kv-100-copper-trxlpe-urd-csa-single-phase-full-neutral-medium-voltage-utility-cables-qbb01zc","provider":"NassauElectrical","version":"1.0","type":"link"}