{"product_id":"prysmian-cable-1-solid-25kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qon000a","title":"Prysmian Cable 1 Solid 25kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QON000A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1 Solid 25kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QON000A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection Prysmian Cable 1 Solid 25kV EPR URD 100% Aluminum Three Phase One Third Neutral Medium Voltage Utility Cables QON000A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable Price, 25kV EPR URD 100% Aluminum Medium Quote, 25kV EPR URD 100% Aluminum Medium Cable, 25kV EPR URD 100% Aluminum Medium Price, Medium Voltage Utility Cable Quote, Medium Voltage Utility Cable Quote Price, Medium Voltage Utility Cable Quote, QON000A, 1 Solid 25kV EPR Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Solid bare copper wires, helically applied and uniformly spaced.  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\n        Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e\n        • Black LLDPE jacket with no stripes \u003cbr\u003e\n        • Black PVC jacket sleeved over separator tape \u003cbr\u003e\n        • No Jacket \u003cbr\u003e\n        • Multiplex cables \u003cbr\u003e\n        • Tinned round and flat strap neutrals \u003cbr\u003e\n        • Strandseal® \u003cbr\u003e\n        • Compact stranded conductors \u003cbr\u003e\n        • UL MV-90 Rating if required \u003cbr\u003e\n        • 46kV \u003cbr\u003e\n        • RUS - Bulletin 1728F-U1 \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e \u003cbr\u003e\n        • Conduit in Air \u003cbr\u003e\n        • Underground Duct \u003cbr\u003e\n        • Wet Locations \u003cbr\u003e\n        • With Messenger \u003cbr\u003e\n        • Direct Buried \u003cbr\u003e\n        • Isolated in Air \u003cbr\u003e\n        • Dry Locations \u003cbr\u003e\n        • Utility Primary \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications and ratings:\u003c\/strong\u003e \u003cbr\u003e\n        • AEIC- AEIC CS8 \u003cbr\u003e\n        • ICEA- ICEA S-94-649 \u003cbr\u003e\n        • For 105°C continuous, 140°C emergency, 250°C short-circuit operation.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor\u003c\/td\u003e\n                    \u003ctd\u003e1 SOLID AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econcentric neutral\u003c\/td\u003e\n                    \u003ctd\u003e6-#14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (in) - (a)\u003c\/td\u003e\n                    \u003ctd\u003e0.289\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (in) - (b)\u003c\/td\u003e\n                    \u003ctd\u003e0.86\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (in) - (c)\u003c\/td\u003e\n                    \u003ctd\u003e0.93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ejacket diameter (in) - (d)\u003c\/td\u003e\n                    \u003ctd\u003e1.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lbs\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e611\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (in)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e159\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e273\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e53\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c in duct\u003c\/td\u003e\n                    \u003ctd\u003e835\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ezero sequence impedance reactance (µΩ\/ft)†† - 105°c in duct\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e† ampacity (amps) - 90°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e211\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance resistance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e281\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e+\/- sequence impedance reactance (µΩ\/ft) - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e101\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance resistance (µΩ\/ft)†† - 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e816\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ezero sequence impedance reactance (µΩ\/ft)††- 105°c direct buried\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQON000A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187748618303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Aluminum_20Medium_20Voltage_20Utility_20Cable-LG_2e178b80-d5b7-4e12-aabe-3a9655d1a423.jpg?v=1571729311","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-cable-1-solid-25kv-epr-urd-100-aluminum-three-phase-one-third-neutral-medium-voltage-utility-cables-qon000a","provider":"NassauElectrical","version":"1.0","type":"link"}