{"product_id":"prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026041m","title":"Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026041M, 777 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e394.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.610\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e40.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e774\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e754\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e822\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e881\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,101\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e3,570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5,315\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026041M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187655819327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_68d732ac-788f-4077-a26f-b1e1fb1d7a4c.jpg?v=1571729257","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026041m","provider":"NassauElectrical","version":"1.0","type":"link"}