{"product_id":"prysmian-and-draka-cable-3-c-250-kcm-low-voltage-airguard-harsh-environments-heavy-industrial-offshore-vfd-600-volt-power-cable-20127514","title":"Prysmian and Draka Cable 3\/C #250 KCM Low Voltage AIRGUARD harsh environments heavy industrial offshore VFD 600 Volt Power Cable *20127514","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3\/C #250 KCM Low Voltage AIRGUARD harsh environments heavy industrial offshore VFD 600 Volt Power Cable *20127514\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable 3\/C #250 KCM Low Voltage  Cable,Prysmian and Draka Cable ,Draka Cable Low Voltage Cable, Draka Cable Low Voltage  Quote,Low Voltage AIRGUARD harsh  Price, Low Voltage AIRGUARD harsh Quote, Low Voltage AIRGUARD harsh environments heavy industrial Price, Low Voltage AIRGUARD harsh environments heavy industrial Quote, Low Voltage AIRGUARD harsh environments heavy industrial offshore VFD 600 Volt Power Cable, Low Voltage AIRGUARD harsh environments heavy industrial offshore VFD 600 Volt Power Cable Quote.\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3\/C #250 KCM Low Voltage AIRGUARD harsh environments heavy industrial offshore VFD 600 Volt Power Cable *20127514 Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003e\n        Conductor:\u003c\/strong\u003e Class B stranded bare, soft drawn copper\n        circuit conductors \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Heat and moisture resistant cross-linked\n        polyethylene (XLPE) meeting the requirements of\n        UL-44 for Type XHHW-2 conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFillers:\u003c\/strong\u003e Extruded filler belt \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGround Wires:\u003c\/strong\u003e Class B stranded bare, soft drawn\n        copper ground conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003e\n        Emi Shield:\u003c\/strong\u003e Metallic tape provides 100% coverage\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePolmeric Aromor\/Enviromental Barrier:\u003c\/strong\u003e\n        Foamed polymeric AIRBAG™ layer affords superior\n        mechanical \u0026amp; environmental protection of the cable core \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath:\u003c\/strong\u003e\u003cbr\u003e\n         Heat, moisture, hydrocarbon, and sunlight\n        resistant thermoplastic \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e\n        Prysmian’s Low Voltage AIRGUARD™ Power Cables are\n        primarily designed for applications in the harsh environments\n        found in the heavy industrial and offshore markets.\n        Its rugged polymeric AIRBAG™ armor and chemical\n        barrier protection package makes it the ideal cable choice\n        for tough harsh environmental conditions. AIRGUARD™\n        provides the solution to the deficiencies often encountered\n        with MC-HL cables including armor breakage encountered\n        during installation and in applications requiring recurring\n        bending after installation, as well as poor performance in\n        areas of high vibration (e.g. motor connections). It also\n        provides a safer and lower installed cost alternative to\n        MC-HL cables due to faster, “No Knife\/ No Saw” cable\n        preparation and substantially reduced cost of cable glands\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eASTM B3 \u0026amp; ASTM B8\u003c\/strong\u003e\u003cbr\u003e\n        Class B Soft Drawn Concentric\n        Lay Stranded Bare Copper\n        Conductors\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eICEA S-82-658 (NEMA WC70)\u003c\/strong\u003e\u003cbr\u003e\n        Power Cable Rating\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL 44 (XHHW-2) 600V\u003c\/strong\u003e\u003cbr\u003e\n        XHHW-2 Multiple Conductors\n        Direct Buried\n        Sunlight Resistant\n        O il Resistant IEEE 1202\/FT-4 Flame Retardant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL 1277 NEC Article 336.10(7)\u003c\/strong\u003e \u003cbr\u003e\n        TC-ER Exposed Run Rating \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL 2225 NEC Article 501.10(A)(2)(3) \u003c\/strong\u003e\u003cbr\u003e\n        TC-ER- HL Class I Division 1 Hazardous Locations\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNEC Article 505.15(B)(1)(i)\u003c\/strong\u003e \u003cbr\u003e\n        TC-ER-HL Class I Zone 1\n        Hazardous Locations\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA 22.2 No. 03\u003c\/strong\u003e\u003cbr\u003e\n        -40oC\/ -35oC Cold Bend\/\n        Cold Impact\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMSHA\u003c\/strong\u003e\u003cbr\u003e\n        Mine Safety \u0026amp; Health\n        Administration\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber and circuit conductor size\u003c\/td\u003e\n                    \u003ctd\u003e3\/c #250 kcm\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of grounding conductor - (#)\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness - (mils)\u003c\/td\u003e\n                    \u003ctd\u003e65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eground wires size - (awg)\u003c\/td\u003e\n                    \u003ctd\u003e8 awg\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter - (inches)\u003c\/td\u003e\n                    \u003ctd\u003e0.558\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal overall insulation(od) - (inches)\u003c\/td\u003e\n                    \u003ctd\u003e0.70\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal overall cable (od ) - (inches)\u003c\/td\u003e\n                    \u003ctd\u003e1.98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enominal cable weight - (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e4024\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius - (inches)\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e‡ ampacity (amps) - (‡90°c)\u003c\/td\u003e\n                    \u003ctd\u003e290\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003egland, explosion proof, class 1 division 1,barrier type\u003c\/td\u003e\n                    \u003ctd\u003e424bt07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e*20127514\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187580846143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Low_20Voltage_20AIRGUARD-Lg_e76b37a7-a7a9-4169-ba3c-e093da0cd391.jpg?v=1571729222","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-and-draka-cable-3-c-250-kcm-low-voltage-airguard-harsh-environments-heavy-industrial-offshore-vfd-600-volt-power-cable-20127514","provider":"NassauElectrical","version":"1.0","type":"link"}