{"product_id":"prysmian-and-draka-cable-2-cores-7-elements-1-5-cross-section-rfcuc-250v-instrumentation-collective-screened-halogen-free-cable-840176","title":"Prysmian and Draka Cable 2 Cores 7 Elements 1.5 Cross-section RFCU(c) 250V Instrumentation Collective Screened Halogen free Cable 840176","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 7 Elements 1.5 Cross-section RFCU(c) 250V Instrumentation Collective Screened Halogen free Cable 840176\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 7 Elements 1.5 Cross-section RFCU(c) 250V Instrumentation Collective Screened Halogen free Cable 840176. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840176, Draka Cable 840176, 2 Cores 7 Elements 1.5 Cross-section RFCU(c) 250V Instrumentation Collective Screened  Halogen free Cable 840176, 840176, RFCU(c) Cable, Instrumentation Cable, Collective Screened Cable, Flame Retardant Cable, Halogen Free Cable, Type P Cable, Rig \u0026amp; Marine Cable, Marine Cable, Tinned Flexible Circular Copper Conductor Cable, EPR Insulation Cable, RFCU(c) 250V Instrumentation Collective Screened Flame Retardant, Halogen free Cable with enhanced oil resistance\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned flexible circular copper, 0.75, 1.0 \u0026amp; 1.5 sqmm (BS6360 class 5)\u003cbr\u003e\n        • Tinned stranded circular copper, 2.5 sqmm (BS 6360, class 2)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad twisting\u003c\/strong\u003e: Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with aluminum backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape Over Inner Covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape Over Armour Screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"metre mark\" \"year\" \"DRAKA\" \"RFCU(C)\" \"UKOOA code\" \"150\/250V\" \"number of pair, triples or quads\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-White, numbered 1-1, 2-2, 3-3....\u003cbr\u003e\n        • Triple - Black-White-Red, numbered 1-1-1, 2-2-2, 3-3-3...\u003cbr\u003e\n        • Quad - Black-White-Red-Blue, numbered 1-1-1-1, 2-2-2-2...\u003cbr\u003e\n        • Each core is identified by contrasting numerals \u0026amp; words repeated along the whole length of the cable.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 or 5 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU(C) 250V 2PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 3PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 3PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 5PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 7PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 7PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 12PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 12PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 19PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 20PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 20PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 27PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 27PAIR 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 2PAIR 1mm2\u003cbr\u003e\n        • RFCU(C) 250V 3PAIR 1mm2\u003cbr\u003e\n        • RFCU(C) 250V 2PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 3PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 3PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 5PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 7PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 12PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 20PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 27PAIR 1.5mm2\u003cbr\u003e\n        • RFCU(C) 250V 3TRIP 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 3TRIP 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 7TRIP 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 12TRIP 0.75mm2\u003cbr\u003e\n        • RFCU(C) 250V 12TRIP 1.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • GREY\u003cbr\u003e\n        • BLUE\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign Standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1991\u003cbr\u003e\n        • BS 6883 : 1999\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e18.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e850\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e183\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ekjj02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840176\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185944969279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_c_20250V_20Instrumentation_20Cable-lg_01f6ef55-0b26-48ab-9895-6e53b9080cb5.jpg?v=1571728972","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-and-draka-cable-2-cores-7-elements-1-5-cross-section-rfcuc-250v-instrumentation-collective-screened-halogen-free-cable-840176","provider":"NassauElectrical","version":"1.0","type":"link"}