{"product_id":"prysmian-and-draka-cable-2-cores-3-elements-1-5-cross-section-bfcuc-250v-instrumentation-collective-screened-armoured-cable-840132","title":"Prysmian and Draka Cable 2 Cores 3 Elements 1.5 Cross-section BFCU(C) 250V Instrumentation Collective Screened Armoured Cable 840132","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 3 Elements 1.5 Cross-section BFCU(C) 250V Instrumentation Collective Screened Armoured Cable 840132\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 3 Elements 1.5 Cross-section BFCU(C) 250V Instrumentation Collective Screened  Armoured Cable 840132. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840132, Draka Cable 840132, 2 Cores 3 Elements 1.5 Cross-section BFCU(C) 250V Instrumentation Collective Screened  Armoured Cable 840132, 840132, BFCU Cable, Instrumentation Cable, Collective Screened Cable, Fire Resistant Cable, Flame Retardant Cable, Halogen free Cable, Armoured Cable, Tinned flexible Copper Cable, EPR Insulation Cable, Galvanized steel wire braid Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, BFCU(C) 250V Instrumentation Collective Screened Fire Resistant, Flame Retardant, Halogen free, Armoured Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned flexible circular copper, 0.75, 1.0 \u0026amp; 1.5 sqmm (BS6360 class 5)\u003cbr\u003e\n        • Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: Mica Glass Tape \/ EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003ePair\/Triple\/Quad twisting\u003c\/strong\u003e: Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with a aluminum backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner Covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoplastic EP-rubber based compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape Over Inner Covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/Screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape Over Armour\/Screen\u003c\/strong\u003e: PET tape + rubberised Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking Text\u003c\/strong\u003e: \"metre mark\" \"year\" \"DRAKA\" \"BFCU(C)\" \"UKOOA code\" \"150\/250V\" \"number of paris, triples or quads\" \"conductor size\" \"BS7917\" \"IEC60331-21\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter Sheath Colour\u003c\/strong\u003e: Grey or Blue\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore Identification\u003c\/strong\u003e:\u003cbr\u003e\n        • Pair - Black-White, numbered 1-1, 2-2, 3-3....\u003cbr\u003e\n        • Triple - Black-White-Red, numbered 1-1-1, 2-2-2, 3-3-3.....\u003cbr\u003e\n        • Quad - Black-White-Red-Blue, numbered 1-1-1-1, 2-2-2-2.....\u003cbr\u003e\n        • Each core is identified by constrasting number \u0026amp; words repeated along the whole length of the cable.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 250V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS7917\/BS6883\/UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 or 5 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 \u0026amp; 3-22 - Flame Retardant\u003cbr\u003e\n        • IEC60331-21 - Fire Resistant\u003cbr\u003e\n        • IEC60754-1,2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1,2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • BFCU(C) 250V 2PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 2PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 5PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 5PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 7PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 7PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 12PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 12PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 19PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 19PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 20PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 20PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 27PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 27PAIR 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 1mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 1mm2\u003cbr\u003e\n        • BFCU(C) 250V 2PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 2PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 5PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 5PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 7PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 7PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 12PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 12PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 20PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 20PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 27PAIR 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 3PAIR 2.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 12PAIR 2.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 3TRIP 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 7TRIP 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 12TRIP 0.75mm2\u003cbr\u003e\n        • BFCU(C) 250V 2TRIP 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 7TRIP 1.5mm2\u003cbr\u003e\n        • BFCU(C) 250V 12TRIP 1.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e:\u003cbr\u003e\n        • BLUE\u003cbr\u003e\n        • GREY\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign Standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1991\u003cbr\u003e\n        • BS 7917 : 1999\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno of cores in element\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of elements\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eApprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e14.5 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e19 ± 0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003egnh02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840132\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185942937663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/BFCU_C_20250V_20Instru._20Collect_20Cable-lg_c9697155-354e-4972-9ebb-f7eb82c5d6c2.jpg?v=1571728971","url":"https:\/\/www.nassauelectrical.com\/products\/prysmian-and-draka-cable-2-cores-3-elements-1-5-cross-section-bfcuc-250v-instrumentation-collective-screened-armoured-cable-840132","provider":"NassauElectrical","version":"1.0","type":"link"}