General Cable Anaconda® Brand Type SHD-BGC 3/0 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

General Cable Anaconda® Brand Type SHD-BGC 3/0 Gauge Power Shielded Round Portable w/Extensible Ground-Check EPR CPE 5000 Volts Three Conductor

Product Details

Conductor: 1 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
  
Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor
Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrasting with black conducting layer 
Insulation Shield: A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape
Ground-Check Conductor:
• Coated copper, specially stranded to provide extensibility without sustaining tensile load, thereby providing maximum resistance to flex fatigue
• Insulated with high-strength polypropylene and placed in the center interstice
Grounding Conductors: Three coated copper, rope-lay-stranded per ASTM B172 in contact with the flexible braid shield
Jacket: Reinforced, two-layer, extra-heavy-duty, leadcured Chlorinated Polyethylene (CPE)
Jacket Marking: GENERAL CABLE® ANACONDA® BRAND (SIZE) 3/C TYPE SHD-BGC 5000 VOLTS (-50C) FT1 FT5 CSA LR 27161 P-7K-102-046 MSHA
Options:
• Colored jackets are available
• TPU (Thermoplastic Polyurethane) jacket
• Anamaxx® jacket 
Applications:
• Designed for use as a trailing cable on AC mining equipment:
- Where maximum safety is mandatory, including underground mining machines where induced voltages in an unbalanced grounding system could be hazardous
- On low- and medium-voltage AC circuits where shielding is desired or required
 Features:
• Flexible insulation shield provides shock hazard protection
• Symmetrical grounding system does not produce induced voltages when operating in a balanced 3-phase system
• Excellent heat, moisture, steam, oil, chemical and radiation resistance
• Flexible for easy handling
• Resists cutting, impact, abrasion, flame and sunlight
• Excellent thermal stability and physical properties over a broad temperature range
• Two-layer jacket is reinforced to provide maximum protection from mechanical damage —the cause of most portable cable failures 
Compliances:
• ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection 
• Meets CAN/CSA C22.2 No. 96 Portable Power Cables and is certified by Natural Resources Canada
Packaging: Material cut to length and shipped on nonreturnable reels
technical specifications:
cond. size(awg/kcmil) 3/0
no. of cond. 3
cond. strand
413
nominal insulation thickness(inches) 0.110
nominal insulation thickness(mm) 2.8
grd. cond. size(awg)
4
grd-check cond. size (awg)
16
nominal jacket thickness(inches)
0.235
nominal jacket thickness(mm)
6.0
nominal cable 0.d.(inches) 2.36
nominal cable 0.d.(mm) 59.94
copper weight(lbs/1000 ft) 2279
copper weight(kg/km) 3391
net weight(lbs/1000 ft) 4729
net weight(kg/km) 7037
ampacity 279
catalog number 16299.065300.ca