General Cable Duralox® XLPE AIA PVC 12/4 AWG Type MC Multi-Conductor Control Armored 600V UL 346530

General Cable Duralox® XLPE AIA PVC 12/4 AWG Type MC Multi-Conductor Control Armored 600V UL 346530

Select gauge from drop-down menu for prices:

General Cable Duralox® XLPE AIA PVC 12/4 AWG Type MC Multi-Conductor Control Armored 600V UL 346530

Product Details

Conductor:
• 14 AWG thru 10 AWG bare compressed copper
• Class B stranding per ASTM B3 and B8

Insulation:
• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-2 (does not include white or green)

Ground: Annealed bare copper Class B stranding per ASTM B8

Armor: Aluminum Interlocked Armor (AIA)

Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• In all raceways or direct burial
• In wet or dry locations
• Permitted for use per NEC Article 334
- Class I, Division 2
- Class II, Division 2
- Class III, Divisions 1 and 2

Features:
• Rated at 90?C wet or dry
• Sunlight-resistant
• Provides excellent oil and chemical resistance
• Excellent crush resistance
• Provides a long service life
• Flame-retardant and resistant to moisture
• Cost-effective alternative to installations in conduit
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 1569
• UL 44
• ICEA S-95-658/NEMA WC70
• UL Type MC-600 volts, UL File # E90496
• NEC Type XHHW-2 conductors

Flame Test Compliances:
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging: Material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specification:
cond. size (awg) 12
no. of cond. 4
minimum insulation thickness(inches) 0.030
minimum insulation thickness(mm) 0.76
grnd. wire size (awg) 12
nom. dia. (over) armor(inches) 0.60
nom. dia. (over) armor(mm) 15.3
nominal jacket thickness(inches) 0.050
nominal jacket thickness(mm) 1.27
nominal cable o.d.(inches) 0.71
nominal cable o.d.(mm) 18.1
copper weight(lbs/1000 ft) 103
copper weight(kg/km) 154
net weight(lbs/1000 ft) 272
net weight(kg/km) 405
general cable part number 346530
service wire part number AAP12/4