• Type RA90 XLPE 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW

    Type RA90 XLPE 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW

    Select gauge from drop-down menu for prices:

    Type RA90 XLPE 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW

    Free Shipping

    No End Date

    Click to View Shopping Cart

    Product Details

    Conductor:
    • Bare annealed copper per ASTM B3 
    • Sizes 10 AWG and smaller are Class B compressed stranding per ASTM B8 
    • Sizes 8 AWG and larger are compact stranding per ASTM B496

    Insulation: 
    • Cross-linked Polyethylene (XLPE) insulation rated 1000 Volts, RW90 per CSA C22.2 No. 38 
    • Sizes 2 AWG and smaller utilize a single color insulation: black, red and blue 
    • Sizes 1 AWG and larger utilize black insulation with printed number/color, 1-black, 2-red, 3-blue

    Bonding/Grounding Conductors: 
    • Class B stranded bare annealed copper per ASTM B3 and B8 
    • Three (3) symmetrical grounding wires are sized in accordance with CEC Table 16

    Cable Assembly: 
    • Three symmetrical grounding wires are cabled within the interstices of the phase conductors 
    • Non-hygroscopic fillers when required 
    • A binder tape is applied over the cabled core

    CCW Armor:  Impervious, continuously welded and corrugated aluminum alloy sheath per C22.2 No. 123

    Jacket: 
    • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black 
    • Meets CSA Low Gas Emission requirements, AG14

    Applications: 
    • Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for   use with AC motors controlled by pulse-width modulated inverters in VFD applications 
    • CCW armored cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods 
    • For use in industrial and commercial installations including hazardous locations in accordance with the CEC 
    • Can be installed in wet or dry locations, indoors or outdoors, in cable trays, in a raceway, or direct buried in accordance with the CEC

    Features: 
    • 90°C, 1000 V wet or dry XLPE insulation and three (3) symmetrical grounding wires, recommended for use with pulse-width modulated AC    drives 
    • XLPE insulation has a dielectric constant less than 3.0 to withstand momentary voltage spikes common with VFD applications  
    • CCW armor provides an impervious barrier to moisture, gas and liquids 
    • CCW armor provides EMI shielding performance 
    • Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems 
    • Meets cold impact at -40°C 
    • 90°C continuous operating temperature, wet or dry 
    • 130°C emergency rating 
    • 250°C short circuit rating

    Specifications:

    Design Adherence: 
    • CSA C22.2 No. 38 Thermoset- Insulated Wires and Cables 
    • CSA C22.2 No. 123 Metal Sheathed Cables 
    • CSA C22.2 No. 174 Cables and Cable Glands for Use in Hazardous Locations

    Flame Tests: 
    • CSA FT4 
    • ICEA T-29-520 (210,000 BTU/hr) 
    • IEEE 383 (70,000 BTU/hr) 
    • IEEE 1202 (70,000 BTU/hr)

    Compliances: 
    • CSA Certified Type RA90, XLPE, HL, SR, FT4, AG14 and -40°C, CSA File # 7319 
    • RoHS Compliant

    cond.size
    (awg/kcmil)
    no. of
    cond.
    insulation
    thickness
    bare
    ground
    cond.
    (awg)
    nominal
    armor o.d.
    jacket
    thickness
    nominal
    overall o.d.
    approximate
    net
    weight
    min.
    bend
    radius ¹
    90°c
    ampacity@
    30°c
    ambient²
    General Cable
     Part Number
    mils mm inches mm mils mm inches mm lbs/1000 ft kg/1000 m inches mm
    12 (7/w)
    (3.31 mm²)
    3 45 1.14 3 x #18 0.60 15.3 50 1.27 0.70 17.8 249 370 7.0 178 30 9675.01203318
    10 (7/w)
    (5.26 mm²)
    3 45 1.14 3 x #16 0.63 16.1 50 1.27 0.73 18.6 299 445 7.3 185 40 9675.01003316
    8 (7/w)
    (8.36 mm²)
    3 45 1.14 3 x #14 0.76 19.2 50 1.27 0.86 21.9 417 620 8.6 218 55 9675.00803314
    6 (7/w)
    (13.3 mm²)
    3 60 1.52 3 x #12 0.91 23.2 50 1.27 1.02 26.0 601 895 12.2 311 75 9675.00603312
    4 (7/w)
    (21.2 mm²)
    3 60 1.52 3 x #12 0.98 24.8 50 1.27 1.08 27.4 763 1,135 12.9 329 95 9675.00403312
    2 (7/w)
    (33.6 mm²)
    3 60 1.52 3 x #10 1.18 29.9 50 1.27 1.28 32.5 1,122 1,670 15.4 390 130 9675.00203310
    3 80 2.03 3 x #10 1.36 34.6 50 1.27 1.46 37.1 1,404 2,090 17.5 445 145 9675.00103310
    1/0 (19/w)
    (53.5 mm²)
    3 80 2.03 3 x #10 1.42 36.0 50 1.27 1.52 38.6 1,623 2,415 18.2 462 170 9675.11003310
    2/0 (19/w)
    (67.4 mm²)
    3 80 2.03 3 x #10 1.56 39.6 50 1.27 1.66 42.2 2,043 3,040 20.0 506 195 9675.21003310
    4/0 (19/w)
    (107 mm²
    3 80 2.03 3 x #8 1.75 44.4 50 1.27 1.85 47.0 2,950 4,390 22.2 564 260 9675.41003308
    250 (37/w)
    (127 mm²)
    3 90 2.29 3 x #8 1.90 48.2 50 1.27 2.01 51.1 3,380 5,030 24.1 612 290 9675.25003308
    350 (37/w)
    (177 mm²)
    3 90 2.29 3 x #8 2.22 56.4 50 1.27 2.33 59.2 4,465 6,645 27.9 710 350 9675.35003308
    500 (37/w)
    (253 mm²)
    3 90 2.29 3 x #6 2.48 63.0 50 1.27 2.59 65.8 6,152 9,155 31.0 789 430 9675.50003306

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image