General Cable Type MC-HL XLPE 1/0 Gauge 2000V Armored Power 3/C VFD UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

General Cable Type MC-HL XLPE 1/0 Gauge 2000V Armored Power 3/C VFD UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Select gauge from drop-down menu for prices:

General Cable Type MC-HL XLPE 1/0 Gauge 2000V Armored Power 3/C VFD UL Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Product Details

Conductor:
• Bare annealed copper per ASTM B3 
• 10 AWG and smaller are Class B compressed stranding per ASTM B
• 8 AWG and larger are compact standing per ASTM B496

Insulation:
• Cross-linked Polyethylene (XLPE) insulation, 2000 V thicknesses per ICEA S-95-658 
• Color-coded black with printed numbers per ICEA Method 4

Grounding Conductors:
• Class B stranded bare annealed copper per ASTM B3 and B8 
• Three (3) split grounding wires per specification 9615 exceed the minimum required in NEC Table 250.122

Cable Assembly: 
• Insulated conductors and grounding wires are cabled together with nonhygroscopic fillers when required 
• A binder tape is applied over the cabled core 

CCW Armor: 
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569 and UL 2225 
• CCW armor conductivity meets the grounding requirements of NEC Article 250

Jacket: 
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) — Black 
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

Applications: 
• Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires is the preferred wiring method for use with AC  motors controlled by pulse-width modulated Inverters in VFD applications 
• CCW armored cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods 
• For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502 and 503 
• For use as services, feeders and branch circuits for power, lighting, control, and signal circuits in accordance with NEC Articles 330 and 725 
• Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as aerial cable on a messenger, in cable trays, or as  exposed runs secured to supports in accordance with NEC Article 330 
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

Features: 
• 90°C, 2000 V rated XLPE insulation with a dielectric constant less than 3.0 to withstand momentary voltage spikes common in certain VFD applications 
• Three (3) oversized, symmetrical grounding wires recommended for use with pulse-width modulated AC drives 
• CCW armor provides an impervious barrier to moisture, gas and liquids  
• CCW armor provides EMI shielding performance 
• Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems 
• Meets cold impact at -40°C 
• 90°C continuous operating temperature, wet or dry 
• 130°C emergency rating 
• 250°C short circuit rating

Specifications:
Design Adherence:
 • ICEA S-95-658/WC70 Standard for Non-Shielded Power Cable, 2 kV or Less 
• UL 44 Rubber Insulated Wires and Cables 
• UL 1569 Metal Clad Cables 
• UL 2225 Cables and Cable Fittings for Use in Hazardous Locations 
• UL 1309 Marine Shipboard Cable

Flame Tests: 
• ICEA T-29-520 (210,000 BTU/hr) 
• IEEE 383 (70,000 BTU/hr) 
• CSA FT4 
• IEEE 1202 (70,000 BTU/hr) 
• UL 1581 (70,000 BTU/hr) 
• IEC 332-3 Cat. A

Compliances: 
• UL Type MC-HL, SUN RES, CT USE, DIR BUR, -40°C, UL File # E90496 
• UL Listed Marine Shipboard, UL File # E85994 
• American Bureau of Shipping (ABS) Listed for CWCMC 
• RoHS Compliant

technical specification:
cond. size (awg/kcmil) 1/0 (19/w) (53.5 mm²)
no. of cond. 3
insulation thickness (mils) 90
insulation thickness (mm) 2.29
bare ground (awg) 3 x #10
nominal core o.d. (inches) 1.21
nominal core o.d. (mm) 30.6
nominal armor o.d. (inches) 1.55
nominal armor o.d. (mm) 38.0
jacket thickness(mils)
60
jacket thickness (mm) 1.52
nominal overall o.d. (inches) 1.68
nominal overall o.d. (mm) 41.2
approximate net weight (lbs/1000 ft) 1,930
approximate net weight (kg/1000 m) 2,872
90°c ampacity @ 30°cambient¹ 170
catalog number 9615.11003310