• Type MC-HL Armored Power 2.4kV Nonshielded 3/C VFD UL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW

    Type MC-HL Armored Power 2.4kV Nonshielded 3/C VFD UL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW

    Select gauge from drop-down menu for prices:

    Type MC-HL Armored Power 2.4kV Nonshielded 3/C VFD UL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW

    Free Shipping

    No End Date

    Click to View Shopping Cart

    Product Details

    Conductor:
    • Bare annealed copper per ASTM B3 
    • Compact stranding per ASTM B496

    Extruded Strand Shield (ESS):  Extruded thermoset semi-conductor stress control layer over conductor per ICEA S-96-659 and UL 1072

    Insulation: 
    • 90 mils Ethylene Propylene Rubber (EPR) insulation per ICEA S-96-659 and UL 1072 
    • Insulation is printed 1-black, 2-red and 3-blue for phase identification

    Grounding Conductors: 
    • Three (3) split Class B stranded bare annealed copper grounding conductors 
    • Sized in accordance with UL 1072 and NEC Table 250.122

    Cable Assembly: 
    • Insulated and grounding conductors are cabled together with nonhygroscopic fillers when required 
    • Binder tape is applied over the cabled core

    CCW Armor: 
    • Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and UL 1569 
    • CCW armor conductivity meets the grounding requirements of NEC Article 250

    Jacket: 
    • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow 
    • Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

     Applications: 
    • Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications 
    • CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods 
    • For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330 
    • For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505 
    • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart 
    • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete 
    • Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

    Features: 
    • CCW armor provides an impervious barrier to moisture, gas and liquids and meets the grounding requirements of UL 1072 and the NEC 
    • Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems  
    • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress 
    • Cable meets cold impact at -40°C 
    • 90°C continuous operating temperature, wet or dry 
    • 140°C emergency rating 
    • 250°C short circuit rating

    Specifications: 

    Design Adherence: 
    • ICEA S-96-659/WC71 Standard for Nonshielded Cables Rated 2001 – 5000 Volts 
    • UL 1072 Medium-Voltage Power Cables 
    • UL 1569 Metal Clad Cables 
    • UL 2225 Cables and Cable Fittings for Use in Hazardous Locations 
    • UL 1309 Marine Shipboard Cable

    Flame Tests: 
    • ICEA T-29-520 (210,000 BTU/hr) 
    • IEEE 383 (70,000 BTU/hr) 
    • CSA FT4 
    • IEEE 1202 (70,000 BTU/hr) 
    • UL 1072 
    • IEC 60332-3 Category A

    Compliances: 
    • UL Type MV-90 or MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501 
    • UL Listed Marine Shipboard, UL File # E85994 
    • American Bureau of Shipping (ABS) Listed for CWCMC

    cond. size no.of
    cond.
    insulation
    thickness
    nominal o.d.
    over insulation
    bare
    ground
    nominal
    armor o.d.
    jacket
    thickness
    nominal
    overall o.d.
    approximat
    net weight
    ampacity General Cable
     Part Number
    awg (kcmil) mils mm inches mm awg inches mm inches mm inches mm
    lbs/
    1000ft
    kg/
    1000m
    in air¹ direct
    burial²
    8(7/w)
    (8.36mm²)
    3 90 2.3 0.36 9.1 3 x #12 0.97 24.6 50 1.27 1.08 27.4 570 848 59 85 9700.00803312
    6 (7/w)
    (13.3mm²)
    3 90 2.3 0.38 9.6 3 x #10 1.06 26.9 50 1.27 1.17 29.7 745 1,109 79 105 9700.00603310
    4 (7/w)
    (21.2mm²)
    3 90 2.3 0.43 10.8 3 x #10 1.19 30.2 50 1.27 1.30 33.0 965 1,436 105 135 9700.00403310
    2 (7/w)
    (33.6mm²)
    3 90 2.3 0.48 12.1 3 x #10 1.34 34.0 50 1.27 1.45 36.8 1,275 1,897 140 180 9700.00203310
    1 (19/w)
    (42.4mm²)
    3 90 2.3 0.52 13.1 3 x #8 1.42 36.1 50 1.27 1.53 38.9 1,525 2,269 160 200 9700.00103308
    1/0 (19/w)
    (53.5mm²)
    3 90 2.3 0.55 13.9 3 x #8 1.51 38.4 50 1.27 1.65 41.9 1,840 2,738 185 230 9700.11003308
    2/0 (19/w)
    (67.4mm²)
    3 90 2.3 0.59 14.9 3 x #8 1.60 40.6 60 1.52 1.73 43.9 2,165 3,222 215 260 9700.21003308
    4/0 (19/w)
    (107 mm²)
    3 90 2.3 0.69 17.4 3 x #7 1.83 46.5 60 1.52 1.96 49.8 3,080 4,584 285 335 9700.41003307
    250 (37/w)
    (127 mm²)
    3 90 2.3 0.74 18.7 3 x #7 1.96 49.8 60 1.52 2.09 53.1 3,475 5,171 320 365 9700.25003307

    350 (37/w)
    (177 mm²)
    3 90 2.3 0.83 21.0 3 x #6 2.19 55.6 60 1.52 2.32 58.9 4,710 7,009 395 440 9700.35003306
    500 (37/w)
    (253 mm²)
    3 90 2.3 0.95 24.0 3 x #5 2.45 62.2 60 1.52 2.61 66.3 6,410 9,539 485 530 9700.50003305
    750 (61/w)
    (380 mm²)
    3 90 2.3 1.12 28.3 3 x #4 2.93 74.4 75 1.91 3.10 78.7 9,225 13,728 615 650 9700.75003304
    1000 (61/w)
    (507 mm²)
    3 90 2.3 1.27 32.2 3 x #4 3.41 86.6 75 1.91 3.59 91.2 12,080 17,977 705 730 9700.10003304

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.

    NOW VIEWING

    Type MC-HL Armored Power 2.4kV Nonshielded 3/C VFD UL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW

    Request a Quote

Request a Quote

Receive A Response In 5 Minutes Or Less During Business Hours

Sign up for our newsletter

Register with Nassau today.

Subscribe to Newsletter