{"product_id":"interlocked-armor-power-cable-6-gauge-3-conductor","title":"Interlocked Armor Power Cable - 6 Gauge - 3 Conductor","description":"\u003cmeta charset=\"utf-8\"\u003eInterlocked Armor Power Cable - 6 Gauge - 3 Conductor\u003cmeta name=\"Description\" content=\"This product employs three conductors made from soft bare annealed copper available in compressed or compact stranding.  The copper conductors meet ASTM requirements B-3 for class B copper wire, B-8 for compressed stranded and B-496 for compact stranded conductors.\"\u003e\u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable – 6 Gauge – 3 Conductor,Type MV-105 Non-Shielded Cable,EPR Insulation Cable,Aluminum Armor Cable,Copper Conductor Cable,Power Cable,Armor Cable\"\u003e\u003ctrstyle\u003e\n\u003cp\u003eInterlocked Armor Power Cable 5kV UL Type MV-105 Non-Shielded, EPR Insulation 133% Insulation Level Aluminum Armor Copper Conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product employs three conductors made from soft bare annealed copper available in compressed or compact stranding.  The copper conductors meet ASTM requirements B-3 for class B copper wire, B-8 for compressed stranded and B-496 for compact stranded conductors.  The conductors include a semi-conducting conductor shield.  The conductors are individually insulated with ethylene propylene rubber (EPR) per ICEA S-96-659.  A soft bare annealed copper grounding conductor is included in the assembly which helps to ensure steady conductivity throughout the life of the cable.  The exterior armor of the cable is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor serves as the first line of defense against materials or objects that may pose a threat to the conductors.  The armor is coated with a yellow sunlight-resistant PVC jacket. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable is designed to transmit medium voltages at a maximum conductor temperature of 105°C.  In emergency overload conditions, conductor can tolerate temperatures up to 140°C and in short circuit conditions, the conductor can tolerate temperatures up to 250°C.  The cable is approved for use in wet or dry locations and can be installed indoors or outdoors.  The cable can be installed aerially, in ducts, cable trays, conduits, or direct burial for circuits not exceeding 5,000 volts.  The cable is approved for use in hazardous locations in accordance with National Electric Code. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by the American Society of Testing and Materials, the copper components meet ASTM requirements B-3 for class B copper wire, B-8 for compressed stranded and B-496 for compact stranded conductors.\u003c\/li\u003e\n\u003cli\u003eThe grounding conductor component of this product aligns with ASTM B-3 for soft bare annealed copper and B-8 for Class B stranded copper.\u003c\/li\u003e\n\u003cli\u003eThis conductor complies with UL standard 1072 for medium voltage conductors.  This standard requires that the cable can perform up to expectations in various areas such as maximum conductor temperature and the ability to transmit voltages up to 5,000 volts.\u003c\/li\u003e\n\u003cli\u003eThis cable passes UL and IEEE 383 Flame Test of 70,000 BTU\/hr.  The cable also passes  ICEA flame test of 210,000 BTU\/hr.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors in this cable are soft bare annealed copper compressed stranded conductors aligning with ASTM standard B-8, or compact stranded conductors aligning with ASTM standard B-496.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe conductors are insulated with ethylene propylene rubber; a thermoset material that adds mechanical strength to the conductors while protecting them from corrosive materials. \u003cstrong\u003e \u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe assembly includes a soft bare annealed class B copper ground conductor which helps to ensure steady conductivity for the life of the cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe exterior armor of the cable is an aluminum interlocked tape armor that is also available in galvanized steel.  The armor serves as the first line of defense against materials or objects that may pose a threat to the conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe armor is coated with a yellow sunlight-resistant PVC jacket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e424CU06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e416MC06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151870050367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW302-00603-lg_d673882e-5307-4f95-a35f-b6631bd8c95f.jpg?v=1571727224","url":"https:\/\/www.nassauelectrical.com\/products\/interlocked-armor-power-cable-6-gauge-3-conductor","provider":"NassauElectrical","version":"1.0","type":"link"}