{"product_id":"interlocked-armor-power-cable-500-gauge-3-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Power Cable - 500 Gauge - 3 Conductor - 600 Volt UL Type MC","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eInterlocked Armor Power Cable - 500 Gauge - 3 Conductor - 600 Volt UL Type MC\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"This Interlocked Armor Power Cable utilizes a soft bare annealed Class B copper conductor that aligns with ASTM standards B-3 and B-8.  Annealed copper is a popular alternative to standard copper because the annealing process softens the metal to add flexibility without compromising the copper’s powerful conductive properties.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Interlocked Armor Power Cable – 500 Gauge – 3 Conductor 600 Volt UL Type MC, Medium Voltage Cables, EPR Insulated Cables, Copper Conductors,Type MC XLP VW-1 Cable,XHHW-2 Insulation Cable,Aluminum Armor Cable, Power Cable,Armor Cable,Type MC Cable\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e500\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e6795\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e2.46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e424CU09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e416MC09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eGeneral Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e11298.0365\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNexans item Part #\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e634816\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOmni Cable Part #\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eY150003A\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSouthwire item Part #\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e380618\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003e14 AWG - 10 AWG: ICEA Method 1, Table E-2\u003c\/li\u003e\n            \u003cli\u003e8 AWG - 750 kcmil: ICEA Method 4\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eExplosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\u003c\/li\u003e\n            \u003cli\u003eRain Tight: 416MC series – all nickel-plated brass\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151869886527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW301-00803-lg_e4a1db14-50a7-4053-a179-ab3a48e5b988.jpg?v=1571727224","url":"https:\/\/www.nassauelectrical.com\/products\/interlocked-armor-power-cable-500-gauge-3-conductor-600-volt-ul-type-mc","provider":"NassauElectrical","version":"1.0","type":"link"}