Interlocked Armor Power Cable - 4 Gauge - 3 Conductor - 5KV

Interlocked Armor Power Cable - 4 Gauge - 3 Conductor - 5KV

Interlocked Armor Power Cable - 4 Gauge - 3 Conductor
Technical Specifications:
Size (AWG or kcmil): 4
No. of Conductors 3
Net Weight: 1115
Overall Diameter (Inches): 1.40
Insulation Thickness (Mils): 115
Jacket Thickness (Mils): 50
No. of Strands: 7
Class 1 Div.2 Connector No.: 424CU06
Rain Tight Connector No.: 416MC06

Specifications:

  • Interlocked Armor - Power Cable
  • 5KV UL Type MV-105 or MC, CT Use, 105°C
  • Non-Shielded, EPR Insulation
  • 133% Insulation Level
  • Aluminum Armor
  • Copper Conductor

Application:
For use in harsh environments where maximum conductor protection is required. Used for primary power and feeder circuits in a broad range of commercial and industrial power distribution systems. Approved for use in wet or dry locations at 105°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 5,000 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. National Electric Code approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.

Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:
Ethylene propylene rubber (EPR) per ICEA S-96-659.

Grounding Conductor:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1072.

Armor:
Aluminum interlocked tape armor per UL Standard 1072 and applicable ICEA standards. Also available in galvanized steel armor.

Jacket:
Yellow sunlight-resistant PVC per UL Standard 1072 and applicable ICEA standards.

Flame Tests:

  • UL and IEEE 383 70,000 BTU/hr flame test
  • IEEE 1202 (2AWG and larger) CSA FT4 flame test
  • ICEA 210,000 BTU/hr flame test

Color Code:
ICEA Method 4

Additional Standards:
NEMA WC71

Connectors:

  • Explosion Proof, Class 1 Division 2: 424CU series – exterior components - aluminum, interior components - nickel-plated brass
  • Rain Tight: 416MC series – all nickel-plated brass
  • See 424MA series in Section J.