General Cable VNTC® Nylon PVC Type TC-ER1 4/0 Gauge 3 Conductors Method 4 Color Code Low Voltage Power Unshielded 600V UL

General Cable VNTC® Nylon PVC Type TC-ER1 4/0 Gauge 3 Conductors Method 4 Color Code Low Voltage Power Unshielded 600V UL

Select gauge from drop-down menu for prices:

General Cable VNTC® Nylon PVC Type TC-ER1 4/0 Gauge 3 Conductors Method 4 Color Code Low Voltage Power Unshielded 600V UL
VNTC Nylon PVC Type TC-ER1 4/0 Gauge 3 Conductors Method 4 Color Code Low Voltage Power Unshielded 600V UL

Conductor:
• 14 AWG thru 500 kcmil bare, annealed copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:
• Flame-retardant Polyvinyl Chloride (PVC) with Polymide (nylon)
• Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink

Ground: Uninsulated bare annealed copper per ASTM B3

Jacket: Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC)

Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
• Permitted for Exposed Run (ER) use in accordance with NEC

Features:
• Rated at 90?C dry, 75?C wet
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Provide outstanding sunlight, cold bend and cold impact resistance
• Offer the smallest cable O.D. available for suitable applications
• Provide good oil and chemical resistance
• Provides a long service life
• Meets cold bend test at -25?C
• Meets the crush and impact requirements of Type MC cable

Compliances:
Industry Compliances:
• NEC Type THHN/THWN conductors
• UL 1277 Type TC-ER, UL File # E57179
• UL 1581
• ICEA S-95-658/NEMA WC70

Flame Test Compliances:
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
• RoHS Compliant

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size(awg/ kcmil) 4/0
no. of cond. 3
cond. strand 19W
ground wire size (awg) 4
minimum avg. insulation thickness(inches) 0.059
minimum avg. insulation thickness(mm) 1.50
minimum avg.jacket thickness(inches) 0.080
minimum avg. jacket thickness(mm) 2.03
nominal cable o.d.(inches) 1.545
nominal cable o.d.(mm) 39.24
copper weight(lbs/1000 ft) 2130
copper weight(kg/km) 3170
net weight(lbs/1000 ft) 2630
net weight(kg/km) 3914
catalog number 221560