General Cable GenFree® XLPE Type TC-LS-ER1 12/2 Flat Gauge E-2 Color Code LSZH Control 600V UL

General Cable GenFree® XLPE Type TC-LS-ER1 12/2 Flat Gauge E-2 Color Code LSZH Control 600V UL

Select gauge from drop-down menu for prices:

General Cable GenFree® XLPE Type TC-LS-ER1 12/2 Flat Gauge E-2 Color Code LSZH Control 600V UL
GenFree XLPE Type TC-LS-ER1 12/2 Flat Gauge E-2 Color Code LSZH Control 600V UL

Conductor:
• 14 AWG thru 10 AWG stranded tinned copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1, Table E-2 (does not include white or green)

Jacket: Lead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)

Applications:
• In free air, raceways, aerial or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
• Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression and impact
• Chemical-resistant
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Meets cold bend test at -30?C
• Low-Smoke, Zero-Halogen jacket is environmentally safe
• Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire
• Meets the crush and impact requirements of Type MC cable for 3 or more conductors

Compliances:
Industry Compliances:
• UL 44 Type XHHW-2
• UL 1277 Type TC-LS-ER, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57
• ICEA T-33-655
• RoHS Compliant

Flame Test Compliances:
• UL 1581/UL 2556
• UL 1685 Vertical Flame Test
• IEEE 1202

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
• RoHS Compliant

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size (awg) 12
no. of cond. 2 Flat
cond. strand 7W
minimum avg. insulation thickness(inches) 0.030
minimum avg. insulation thickness(mm) 0.76
minimum avg. jacket thickness(inches) 0.045
minimum avg. jacket thickness(mm) 1.14
nominal cable o.d.(inches) 0.400 x 0.245
nominal cable o.d.(mm) 10.20 x 6.20
copper weight(lbs/ 1000 ft) 40
copper weight(kg/km) 60
net weight(lbs/ 1000 ft) 82
net weight(kg/km) 122
catalog number 394400*