General Cable TC-Flex® Shielded Tray Cable 16/30 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

General Cable TC-Flex® Shielded Tray Cable 16/30 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

Select gauge from drop-down menu for prices:

General Cable TC-Flex® Shielded Tray Cable 16/30 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant
TC-Flex Shielded Tray Cable 16/30 Gauge UL Type WTTC 1000 V or Type TC-ER 600V or Type MTW and c(UL) CIC TC 600V FT4 or CSA AWM 1000 V Flexible Oil Res I/II Sunlight and Flame-Retardant

Conductors: 18 AWG (1,0 mm²) and 16 AWG (1,5 mm²) fully annealed flexible stranded bare copper with Class 5 stranding per EN 60228 (IEC 60228)

Insulation: Polyvinyl Chloride (PVC) insulation with Polyamide (nylon) jacket per UL 83

Conductor Identification: Conductors are black with printed numbers and green/yellow grounding conductor

Cable Assembly: Conductors cabled with non-hygroscopic fillers to make cable suitably round

Shield: Aluminum/Mylar foil shield providing 100% coverage combined with a tinned copper braid with 85% nom. coverage

Jacket: Black, flexible, flame-retardant, sunlight- and oil-resistant Polyvinyl Chloride (PVC) jacket

Minimum Bending Radius:
• 4x O.D. for fixed installation
• 8x O.D. for flexing applications

Applications:
• In free air, raceways or direct burial
• (UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140
• (UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336
• (UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063
• (CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I
• (CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I

Specifications:
Design Adherence:
• UL 66 & UL 83/CSA C22.2 No. 75-08 Thermoplastic Insulated Wires
• UL 1063/MTW Machine Tool Wire
• UL 1277 Power and Control Tray Cables
• UL 2277 Wind Turbine Tray Cables
• CSA C22.2 No. 230-09 Tray Cables
• CSA C22.2 No. 239-09 Control and Instrumentation Cables
• CSA C22.2 No. 210-11 Appliance Wiring Material Products

Flame Tests: IEEE 1202/CSA FT4

Compliances:
• Type TC-ER 90°C Dry, 75°C Wet, 600 V
• Type MTW
• Type WTTC 90°C, 1000 V
• Type CIC/TC 90°C, 600 V
• Type AWM I/II A/B, 90°C, 1000 V FT4
• RoHS Compliant

technical specification:
cond. size (awg) 16
no. of cond. inc. grnd. 30
nom. ins. thickness(inches) 0.021
nom. ins. thickness(mm) 0.53
nom. jacket thickness(inches) 0.085
nom. jacket thickness(mm) 2.16
nom. cable o.d.(inches) 0.877
nom. cable o.d.(mm) 22.3
nom. copper weight(lbs/1000ft) 318
nom. copper weight(kg/km) 473
nom. cable weight(lbs/1000ft) 533
nom. cable weight(kg/km) 793
90°c amp. @ 30°c ambient¹ 6
catalog number 4785.30016*

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question