Helukabel 18 AWG 3 Cores JZ-602-C-PUR Screened Two Approval Control Cable EMC-Preferred Meter Marking 80C 600V Cable 12562

Helukabel 18 AWG 3 Cores JZ-602-C-PUR Screened Two Approval Control Cable EMC-Preferred Meter Marking 80C 600V Cable 12562

Select gauge from drop-down menu for prices:

Helukabel 18 AWG 3 Cores JZ-602-C-PUR Screened Two Approval Control Cable EMC-Preferred Meter Marking 80C 600V Cable 12562
Helukabel 18 AWG 3 Cores JZ-602-C-PUR Screened Two Approval Control Cable EMC-Preferred Meter Marking 80C 600V Cable 12562.

Technical Data: Special PUR-insulated to UL CSA AWM I/II A/B Style 20939 and CSA

Temperature Range: Flexing -5°C to +80°C fixed installation -40°C to +80°C 

Nominal Voltage: UL/CSA 600 V 

Test Voltage: 3000 V 

Breakdown Voltage: Min. 6000 V 

Insulation Resistance: Min. 20 MOhm x km 

Minimum Bending Radius: Flexing 10x cable Ø fixed installation 5x cable Ø 

Radiation Resistance: Up to 100x106 cJ/kg (up to 100 Mrad) Coupling resistance: max. 250 Ohm/km

Cable Structure: 
• Bare copper, fine wire stranded to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5 
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 and UL-Style 10012 
• Core identification to DIN VDE 0293 black cores with continuous white numbering 
• GN-YE conductor, 3 cores and above in the outer layer 
• Cores stranded in layers with optimal lay-length 
• PVC-insulated inner sheath YM5 to DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 
• Braided screen of tinned Cu wires, approx. 85% coverage 
• Outer sheath of full-polyurethane 
• Sheath colour grey (RAL 7001)
• with meter marking 

Properties: 
• Resistant to mineral oils, synthetic oils and coolant, UV-radiation, osygene, ozon and hydrolysis. Conditionally resistant to microbes. 
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers 

Note: 
• G = with green-yellow conductor 
• x = without green-yellow conductor (OZ) 
• AWG sizes are approximate equivalent values. The actual cross-section is in mm². 

Unscreened Analogue Type: JZ-602 PUR 

Application: 
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist, wet and outdoor environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. EMC = Electromagnetic compatibillity To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 18
no.cores x cross-sec.mm² 3 G 1
outer ø app. mm 8,4
cop. weight kg/km 64,0
weight app. kg/km 130,0
helukabel part number 12562