Helukabel 18 AWG 18 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6/1kV Meter Marking Cable 10635

Helukabel 18 AWG 18 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6/1kV Meter Marking Cable 10635

Select gauge from drop-down menu for prices:

Helukabel 18 AWG 18 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6/1kV Meter Marking Cable 10635

Product Details

Technical data: 
• Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 / DIN EN 50525-2-51, with insulation wall thickness for 1 kV

Temperature range: 
• Flexing -15°C to +80°C 
• Fixed installation -40°C to +80°C 

Nominal voltage: 
• U0/U 0,6/1 kV 

Test voltage: 
• 4000 V 

Breakdown voltage: 
• Min. 8000 V 

Insulation resistance: 
• Min. 20 MOhm x km 

Minimum bending radius: 
• Flexing 7,5x cable Ø 
• Fixed installation 4x cable Ø 

Radiation resistance: 
• Up to 80x106 cJ/kg (up to 80 Mrad) 

Cable structure: 
• Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 
• Core identification to DIN VDE 0293 black cores with continuous white numbering 
• GN-YE conductor, 3 cores and above in the outer layer 
• Cores stranded in layers with optimal lay length 
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 
• Sheath colour: black (RAL 9005) 
• With meter marking 

Properties: 
• Extensively oil resistant, oil-/chemical resistance see "Technical Informations" 
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers 
• UV resistant 

Tests: 
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) 

Note: 
• G = with GN-YE conductor, x = without GN-YE conductor (OZ) 
• AWG sizes are approximate equivalent values. The actual cross section is in mm². 
• Screened analogue type: JZ-600-Y-CY 

Application: 
• Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 18
no.cores x cross-sec. mm² 18 x 1
outer ø app. mm 15,7
cop. weight kg/km 173,0
weight app. kg/km 405,0
helukabel part number 10635

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question