Helukabel 14 AWG 7 Cores JZ-600-Y-CY UL/CSA EMC Preferred Type, Number Coded, 1000V Cu-Screened Black Flexible Cable 12381

Helukabel 14 AWG 7 Cores JZ-600-Y-CY UL/CSA EMC Preferred Type, Number Coded, 1000V Cu-Screened Black Flexible Cable 12381

Select gauge from drop-down menu for prices:

Helukabel 14 AWG 7 Cores JZ-600-Y-CY UL/CSA EMC Preferred Type, Number Coded, 1000V Cu-Screened Black Flexible Cable 12381
Helukabel 14 AWG 7 Cores JZ-600-Y-CY UL/CSA EMC Preferred Type, Number Coded, 1000V Cu-Screened Black Flexible Cable 12381

Technical Data
• Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 / DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179

Temperature Range
• Flexing -5°C to +80°C
• Fixed installation -40°C to +80°C

Nominal Voltage
• VDE U0/U 600/1000 V
• UL/CSA 1000 V

Test Voltage
• 4000 V

Breakdown Voltage
• Min.8000 V

Insulation Resistance
• Min. 20 MOhm x km

Minimum Bending Radius
• Flexing 10x cable Ø
• Fixed installation 5x cable Ø

Radiation Resistance
• Up to 80x106 cJ/kg (up to 80 Mrad)

Coupling Resistance
• Max 250 Ohm/km

Cable Structure
• Bare copper fine wire conductors acc. to DIN VDE 0295 cl.5 BS 6360 cl.5 and;IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 and class 43 acc to UL Std 1581
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• PVC-insulated inner sheath TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1, class;43 acc to UL Std.1581
• Braided screen of tinned Cu wires,coverage approx 85%
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 and class 43 acc to UL Std.1581
• Sheath colour: black (RAL9005) or grey (RAL7001)
• With meter marking

Properties
• Extensively oil resistant, oil-/chemical resistance see "Technical;Informations"
• UV resistant (building with black sheath)
• The materials used during manufacturing are cadmium-free contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests
• PVC self-extinguishing and flame retardant acc to DIN VDE 0482-332-1-2, DIN;EN 60332-1-2 IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) UL VW-1 CSA FT1

Note
• G = with GN-YE conductor x = without GN-YE conductor (OZ)
• AWG sizes are approximate equivalent values The actual cross section is in mm².
• Unscreened analogue type: JZ-600 UL/CSA

Application
PVC control cable for measuring,monitoring and control purposes in tool machinery, conveyor belts and production lines in machinery, in air conditioning, in foundries and steel mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath) Is not suitable to be used as direct burrial- or as underwater cable. Interference-free;transmission of signals and pulses is assured by the high degree of screening.

Technical Specification
AWG 14
No.Cores x cross-sec. mm² 7 G 2,5
Outer ø app.mm 17,9
Cop. weight kg/km 284,0
Weight app. kg/km 561,0
Helukabel Part Number 12381

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.