{"product_id":"fxff147-dual-output-flow-sensor-for-liquid-temperature-velocity-measurement","title":"FXFF147 - Dual Output Flow Sensor for Liquid Temperature \u0026 Velocity Measurement","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntroducing the weFlux² Flow Sensors, designed to accurately measure both flow velocity and the temperature of water-based liquids, regardless of their direction or position These sensors feature dual analog outputs, allowing for streamlined data collection By halving the number of measurement points and offering a wide range of sensor variants, they provide unparalleled flexibility in installations for closed piping systems.\u003cbr\u003e\u003cbr\u003e Housed in a compact design, the integrated analysis module enhances efficiency and ease of use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•2 analog outputs: 4 ... 20 mA.\u003c\/p\u003e\n\u003cp\u003e•FDA compliant.\u003c\/p\u003e\n\u003cp\u003e•A single sensor for flow and temperature.\u003c\/p\u003e\n\u003cp\u003e•Measurement independent of flow direction and installation position.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Measuring Range\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 ... 400 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Temperature of the medium, flow measurement\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0 ... 125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Temperature of the medium, temperature measurement\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-25 ... 150 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Setting Range\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 ... 400 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Medium\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eWater\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Measuring error (total)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e≤ 2 %\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e MTTFd (EN ISO 13849-1)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1,210.41 a\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Response time in case of temperature jump\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Ambient temperature\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-25 ... 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Storage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-25 ... 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Pressure Resistance\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e100 bar\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e12 ... 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Current Consumption (Ub = 24 V)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e\u0026lt; 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Number of analog outputs\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Signal source\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eFlow\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Response Time\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1 ... 5 s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Short Circuit Protection\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Protection Class\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Housing Material\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eStainless steel, V4A (1.4404\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Material in contact with media\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eStainless steel, V4A (1.4404\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Degree of Protection\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIP69K * IP68 *\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Connection\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eM12 × 1; 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Process Connection\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eG 1\/2\" hygienic design\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Probe Length (PL)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_8c98c5ad-c8fb-4ae9-8b96-de6c50b3dffe.pdf?v=1746215318\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"WENGLOR","offers":[{"title":"Default Title","offer_id":41670018498623,"sku":"FXFF147","price":498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_1c86034c-7e41-4080-a220-8bdd7674bcff.webp?v=1746215339","url":"https:\/\/www.nassauelectrical.com\/products\/fxff147-dual-output-flow-sensor-for-liquid-temperature-velocity-measurement","provider":"NassauElectrical","version":"1.0","type":"link"}