• Prysmian and Draka Cable Dry FusionLink Armored Ribbon central tube Cable

    Prysmian and Draka Cable Dry FusionLink Armored Ribbon central tube Cable

    Free Shipping

    No End Date

    Click to View Shopping Cart

    Product Details

    Features and Benefits:

    Compact Design:
    • Efficient packaging of higher fiber counts
    • Lightweight and easy to handle during installation

    Easily Removable Ribbon Matrix:
    • Allows for ease of stripping and fiber breakout
    • Improves mid-span strippability

    Precision Ribbon Geometry: Time and labor savings during fiber splicing

    Flexible Buffer Tube:
    • Superior kink resistance
    • Increased flexibility
    • Facilitates route management in closures

    Dry Water-Blocking Technology:
    • Buffer tube and core are completely dry—no gel
    • Permits rapid cable preparation and termination
    • Water-blocking materials are easily removed

    ezPrep® Corrugated Steel Armor:
    • Provides additional mechanical protection
    • Special coating reduces time and effort to remove jacket

    Available Uncoupled or Coupled Designs:
    • Coupled design (RCD product >48F) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application
    • Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures

    Performance:
    • Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
    • Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
    • Complies with RUS PE-90

    Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

    performance specifications
    bend radius
    dynamic
    static
    20 x cable od
    10 x cable od
    tensile rating
    installation
    residual
    n
    2700
    800
    lbf
    600
    180
    crush resistance
    short/ long term
    n/cm
    220/110
    lbf/in
    125/63
    temperature ratings
    operation
    installation
    storage/shipping
    °c
    -40 to +70
    -30 to +60
    -40 to +75
    °f
    -40 to +158
    -22 to +140
    -40 to +167

    Nominal Design Parameters
    fiber
    count
    ribbon
    count
    fibers/
    ribbon
    aerial coupling
    coils required
    (rcd)
    aerial coupling
    coils required
    (rcu)
    buffer tube od cable od cable weight max. length
    (mm) (inches) (mm) (inches) (kg/km) (lb/kft) (m) (ft)
    12-48 1-4 12 non available yes 6.2 0.24 12.5 0.50 152 102 11,187 36,693
    60-72 5-6 12 no yes 8.8 0.35 16.3 0.64 224 151 11,187 36,693
    84-96 7-8 12 no yes 9.5 0.37 17.0 0.67 233 157 10,095 33,111
    108-144 9-12 12 no yes 10.6 0.42 18.1 0.71 258 173 8,880 29,126
    156-216 13-18 12 no yes 12.3 0.48 19.8 0.78 285 192 7,580 24,862
    240-432* 10-18 24 no yes 15.4 0.61 22.9 0.90 353 237 5,445 17,864

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.

    NOW VIEWING

    Prysmian and Draka Cable Dry FusionLink Armored Ribbon central tube Cable

    Request a Quote

Request a Quote

Receive A Response In 5 Minutes Or Less During Business Hours

Sign up for our newsletter

Register with Nassau today.

Subscribe to Newsletter