{"product_id":"ffxf015-uniflow-flow-sensor-for-aqueous-and-oily-media","title":"FFXF015 - UniFlow Flow Sensor for Aqueous and Oily Media","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntroducing the Flow Sensor from Wenglor, designed to accurately measure the flow rate of both aqueous and oily substances in closed piping systems Operating this sensor is effortless, thanks to its detachable cover that reveals an integrated display The clear switching status indicator allows for quick identification of sensors needing maintenance Additionally, the metallic sealing edge on the process connection eliminates the need for extra seals, enhancing the product's reliability.\u003cbr\u003e\u003cbr\u003e Please note, this item has been discontinued, but you can browse for similar products here.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•Measurement independent of flow direction.\u003c\/p\u003e\n\u003cp\u003e•Hygienic design makes it easy to clean.\u003c\/p\u003e\n\u003cp\u003e•Highest precision of its class.\u003c\/p\u003e\n\u003cp\u003e•CIP-capable.\u003c\/p\u003e\n\u003cp\u003e•Temperature of the medium: 0 ... 100° C (140° C for 24 hours without current measurement).\u003c\/p\u003e\n\u003cp\u003e•FDA compliant.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Medium\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eWater\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Measuring range 1\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 ... 150 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Setting range 1\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e15 ... 150 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Measuring range 2\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e20 ... 300 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Setting range 2\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e30 ... 300 cm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Measuring error (total)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e2 %\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e MTTFd (EN ISO 13849-1)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e766.91 a\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Switching Hysteresis\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e5 %\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Temperature gradient\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e30 K\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Response time in case of temperature jump\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e10 s\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Environmental conditions\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e{'Temperature of medium': '0 ... 100 °C', 'Temperature of the medium, short-term': '140 °C', 'Ambient temperature': '-20 ... 70 °C', 'Pressure Resistance': '60 bar', 'EMC': 'DIN EN 60947-5-9', 'Shock resistance per DIN IEC 68-2-27': '30 g \/ 11 ms', 'Vibration resistance per DIN IEC 60068-2-6': '20 g (10...2000 Hz)'}\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Electrical Data\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e{'Supply Voltage': '16 ... 32 V DC', 'Current Consumption (Ub = 24 V)': '60 mA', 'Number of Switching Outputs': '1', 'Analog Output': '0...10 V', 'Signal source': 'Temperature', 'Response Time': '1 ... 5 s', 'Relay Output \/ Switching Current (24 VDC)': '\u0026lt; 1 A', 'Load Current Voltage Output': '\u0026lt; 20 mA', 'Short Circuit Protection': 'yes', 'Reverse Polarity Protection': 'yes', 'Protection Class': 'III'}\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Mechanical Data\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e{'Setting Method': 'Menu', 'Housing Material': 'Stainless steel, V4A (1.4435\/316L), Plastic, PC', 'Material Control Panel': 'Polyester', 'Material in contact with media': 'Stainless steel, V4A (1.4404 \/ 316L), Stainless steel, V4A (1.4435\/316L)', 'Degree of Protection': 'IP69K * IP67 *', 'Connection': 'M12 × 1; 4-pin', 'Process Connection': 'G 1\/2\" CIP-capable', 'Process Connection Length (PCL)': '48 mm', 'Probe Length (PL)': '10 mm'}\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Output\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e{'Analog output temperature': 'yes', 'PNP NO': 'yes', 'Adjustable parameters': 'Circuit NC NC\/NO NO', 'Other parameters': 'Selectable measurement range'}\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_60e0455e-9d96-4593-8fe7-d1646988cdf5.pdf?v=1746134365\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"WENGLOR","offers":[{"title":"Default Title","offer_id":41668345692223,"sku":"FFXF015","price":692.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_e48fc286-e26a-41f5-80df-736e5bbbe060.webp?v=1746134388","url":"https:\/\/www.nassauelectrical.com\/products\/ffxf015-uniflow-flow-sensor-for-aqueous-and-oily-media","provider":"NassauElectrical","version":"1.0","type":"link"}